Whirlpool W10057250 manual Connect Vent, Level Dryer, Reverse Door Swing, Remove the door assembly

Page 16

Connect Vent

1.Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.

2.Move dryer into its final location. Do not crush or kink vent.

3.(On gas models) Check that there are no kinks in the flexible gas line.

4.Once the exhaust vent connection is made, remove the corner posts and cardboard.

Level Dryer

Check the levelness of the dryer. Check levelness first side to side, then front to back.

2.Lay the door assembly on a flat, protected surface with the inside (inner door assembly) facing up.

3.Remove the 6 Phillips head screws to release the outer door assembly from the inner door assembly, as indicated below. See illustration. It is important that you remove only the

6 indicated screws.

4.Lift the inner door assembly off the outer door assembly.

5.Disengage locking tabs by rotating inner ring clockwise. See illustration.

If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness.

Reverse Door Swing

You can change your door swing from a right-side opening to a left-side opening, if desired.

1.Place a towel or soft cloth on top of the dryer or work space to protect the surface.

Remove the door assembly

1.Remove the 4 screws that hold the door hinge on the front panel of the dryer.

A

B

A. Dryer front panel

B. Door assembly

B

A

A. Inner ring

B. Outer ring

6.Turn inner ring 180° and lock tabs into place.

Reverse hinge

1.Use a small flat-blade screwdriver to remove 2 plug strips from the inner door. Slide the head of the screwdriver under the plugs, being certain not to scratch the inner door surface. Lift up.

16

Image 16
Contents Electronic Electric Dryer W10057250Table of Contents Dryer Safety Your safety and the safety of others are very importantTools and Parts Installation InstructionsOptional Pedestal Dryer Dimensions Installation clearancesCustom undercounter installation Dryer only Location RequirementsRecommended installation spacing for cabinet installation Mobile home additional installation requirementsCloset installation Dryer only Recessed or closet installation Dryer on pedestalIt is your responsibility Electrical RequirementsElectrical Connection Style 1 Power supply cord strain relief Power Supply Cord Direct WireElectrical Connection Wire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct wire Remove center silver-colored terminal block screwBDE CG F Optional 3-wire connection Venting Requirements If using an existing vent systemIf this is a new vent system Vent material Optional exhaust installations Alternate installations for close clearancesSpecial provisions for mobile home installations Plan Vent SystemInstall Vent System Install Leveling LegsVent system chart Determine vent pathRemove the door assembly Connect VentLevel Dryer Reverse Door SwingReinstall the door Reverse the strikeComplete Installation If the dryer will not start, check the followingStarting Your Dryer Dryer USETo use an Auto Cycle Lock Controls Stopping or Restarting Your DryerDrying and Cycle Tips Status Lights CyclesAdditional Features End of Cycle Signal Changing Cycles, Options and ModifiersDrying Rack Option Changing Cycles after pressing StartCleaning the Dryer Location Cleaning the Lint ScreenCleaning the Dryer Interior Dryer CareTroubleshooting Removing Accumulated LintVacation and Moving Care Dryer OperationDryer Results Assistance or Service If you need replacement partsFor assistance and service Accessories U.S.AWhirlpool Corporation Major Appliance Warranty W10057250