Whirlpool W10057250 manual Dryer Results

Page 26

Dryer Results

Clothes are not drying satisfactorily, drying times are too long, or load is too hot

Is the lint screen clogged with lint?

Lint screen should be cleaned before each load.

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

Is the exhaust vent or outside exhaust hood clogged with lint, restricting air movement?

Run the dryer for 5-10 minutes. Hold your hand under the outside exhaust hood to check air movement. If you do not feel air movement, clean exhaust system of lint or replace exhaust vent with heavy metal or flexible metal vent. See “Venting Requirements.”

Are fabric softener sheets blocking the grille?

Use only one fabric softener sheet, and use it only once.

Is the exhaust vent the correct length?

Check that the exhaust vent is not too long or has too many turns. Long venting will increase drying times. See “Plan Vent System.”

Is the exhaust vent diameter the correct size? Use 4" (10.2 cm) diameter vent material.

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

Is the dryer located in a room with temperature below 45ºF (7ºC)?

Proper operation of dryer cycles requires temperatures above 45ºF (7ºC).

Is the dryer located in a closet?

Closet doors must have ventilation openings at the top and bottom of the door. The front of the dryer requires a minimum of 1" (2.5 cm) of airspace, and, for most installations, the rear of the dryer requires 5" (12.7 cm). See “Installation Instructions.”

Has the Air Only modifier been selected?

Select the right temperature for the types of garments being dried. See “Additional Features.”

Is the load too large and heavy to dry quickly? Separate the load to tumble freely.

Cycle time too short

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer. Failure to do so can result in back or other injury.

Is the automatic cycle ending early?

The load may not be contacting the sensor strips. Level the dryer.

Change the dryness level setting on Auto Cycles. Increasing or decreasing the dryness level will change the amount of drying time in a cycle.

Do not use a dryer rack with an Auto Cycle.

Lint on load

Is the lint screen clogged?

Clean lint screen. Check for air movement.

Stains on load or drum

Was dryer fabric softener properly used?

Add dryer fabric softener sheets at the beginning of the cycle. Fabric softener sheets added to a partially dried load can stain your garments.

Drum stains are caused by dyes in clothing (usually blue jeans). This will not transfer to other clothing.

Loads are wrinkled

Was the load removed from dryer at the end of the cycle?

Was the dryer overloaded?

Dry smaller loads that can tumble freely.

Odors

Have you recently been painting, staining or varnishing in the area where your dryer is located?

If so, ventilate the area. When the odors or fumes are gone from the area, rewash and dry the clothing.

Is the dryer being used for the first time?

The new electric heating element may have an odor. The odor will be gone after the first cycle.

26

Image 26
Contents Electronic Electric Dryer W10057250Table of Contents Dryer Safety Your safety and the safety of others are very importantOptional Pedestal Installation InstructionsTools and Parts Custom undercounter installation Dryer only Dryer DimensionsInstallation clearances Location RequirementsCloset installation Dryer only Recommended installation spacing for cabinet installationMobile home additional installation requirements Recessed or closet installation Dryer on pedestalElectrical Connection Electrical RequirementsIt is your responsibility Electrical Connection Power Supply Cord Direct WireStyle 1 Power supply cord strain relief Wire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct wire Remove center silver-colored terminal block screwBDE CG F Optional 3-wire connection If this is a new vent system Vent material If using an existing vent systemVenting Requirements Special provisions for mobile home installations Optional exhaust installationsAlternate installations for close clearances Plan Vent SystemVent system chart Install Vent SystemInstall Leveling Legs Determine vent pathLevel Dryer Remove the door assemblyConnect Vent Reverse Door SwingReinstall the door Reverse the strikeComplete Installation If the dryer will not start, check the followingTo use an Auto Cycle Dryer USEStarting Your Dryer Drying and Cycle Tips Stopping or Restarting Your DryerLock Controls Status Lights CyclesAdditional Features Drying Rack Option End of Cycle SignalChanging Cycles, Options and Modifiers Changing Cycles after pressing StartCleaning the Dryer Interior Cleaning the Dryer LocationCleaning the Lint Screen Dryer CareVacation and Moving Care TroubleshootingRemoving Accumulated Lint Dryer OperationDryer Results For assistance and service Assistance or ServiceIf you need replacement parts Accessories U.S.AWhirlpool Corporation Major Appliance Warranty W10057250