Programming special functions
4.Restoring the factory settings
^Turn the program selector to "STOP" f .
^Turn the machine off.
^Press and hold "Display" ß and "Start" 6. At the same time, turn the lab washer on with the "On/Off" button.
The displays shows the current program status "P...".
The "Fill/Drain" indicator lights.
^Press and hold "Drying" 0 until "E33" appears in the display.
^Turn the program selector to any position (except "STOP").
The display shows either "00" or "PP". "00" = factory setting; electronic was not reprogrammed.
"PP" = electronic was reprogrammed.
^If "PP" is displayed press "Display" ß to change from "PP" to "00".
^Press the "Start" 6 button. "SP" appears in the display.
^Press the "Start" 6 button again.
All factory settings are now restored.
If the hardness level setting in the water softener had been changed, this will reset to the factory setting of 340 ppm (19 gr/gal). This will need to be reset to suit the hardness level in your area.
Changes in programs "Custom", "Inorganica" and "Organica" cannot be reset.
42