Electrical connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

WARNING: THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this safety measure not be observed.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance’s rating plate. The rating plate is located at the top of the rim of the open door.

 

Mod

 

Prod. No

P0042

Ser. No

 

The appliance is supplied with a 13amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved (BS1363) fuse must be used.

Should the plug need to be replaced for any reason, proceed as described below.

The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow

- Earth

Blue- Neutral

Brown- Live

GREEN & YELLOW

E

The wire coloured blue must be connected to the terminal marked «N» or coloured black.

The wire coloured brown must be connected to the terminal marked «L» or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

WARNING:

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of safely.

Should the appliance power supply cable need to be replaced, this should be carried out by our Service Force Centre.

Note

When the appliance is installed the power supply cable must be accessible.

Permanent connection

In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at any point.

N

13 A

L

BROWN

BLUE

P1041

CORD CLAMP

 

The wire coloured green and yellow must be connected to the terminal marked with the letter «E» or by the earth symbol or coloured green and yellow.

27

Image 27
Contents WDR 1040 W WDR 1240 W Installation Child SafetyUse Contents Your New Washer-Dryer Ecological hintsInterest Environment Detergent dispenser drawer Description of the ApplianceControl Panel Operating Sequence At the end of the programme Washing 2 KG of Mixed Fabrics AT 50C Select the programmeDrying 2.25 KG of Cotton Select the required timeAutodrying 1 KG of Mixed Fabrics 1000g = 1 kg Washing and Drying HintsWhich form? Which detergent?Important Notes Wash Care SymbolsType of laundry Washing ProgrammesCool MixedFabrics QuickType of fabric Max. load Spin speed Drying ProgrammesMaintenance and Cleaning Water inlet filter Something Not Working Customer Care Service & Spare PartsSymptom Possible causes 0870 5This guarantee does not cover Guarantee ConditionsStandard guarantee conditions European guaranteeDrying Installation InstructionsTechnical Specifications WashingInstallation on a Suspended Floor UnpackingPositioning Water inlet Water drainageAppliance must be connected to a cold water supply Levelling Special conditionsInterest of the environment Permanent connection Electrical connectionConsumer care telephone number 08705