If you cannot make the cold water connection direct from the rising mains, you may be able to operate the appliance from your cold water storage system.
There should be a minimum vertical distance of 5.02m (16.5 ft) between the appliance’s inlet and the bottom of the water storage tank.
Set the hoses correctly by loosening the ring nuts. After positioning the inlet hoses, be sure to tighten the ring nuts again to prevent leaks.
When discharging into a standpipe ensure that the top of the standpipe is no more than 90cm (35.4'') and no less than 60cm (23.6'') above floor level.
3 pin |
|
60 cm (23.6”) | Max. 90 cm (35.4”) |
Min. |
|
P1088 |
P0021 |
P1201 |
The drain hose may be extended to a maximum of 4 metres. An additional drain hose and joining piece is available from your local Service Force Centre.
The joining piece must have an internal diameter of 18mm.
If your drain hose looks like this (see below) you do not require the “U” piece”. Just push the hose firmly into
Water drainage
This appliance is designed to be permanently plumbed into your home's drainage system using one of the following methods.
1. Into a drainage standpipe.
Firstly form a hook in the end of the drain hose using the “U” piece” supplied.
“U” piece supplied
P1199
Place the drain hose into your standpipe, which should have an internal diameter of approximately 38mm thus ensuring there is an air break between the drain hose and standpipe.
38 mm (11.2”)
standpipe diameter
cm30 2")1(
P1200
the standpipe.
P1212
2. Onto a sink outlet spigot.
If the outlet spigot has not been used before, remove any blanking plug that may be in place.
P1197 |
Push the drain hose onto the spigot and secure with a clip, ensure a loop is formed in the drain hose (see diagram) to prevent waste from the sink entering the washing machine.
23