Push up the closing cap1st) (and place the drain hose back in its holder2nd).(
Carefully remove the pump cap.
A little residual water will flow out.
Remove any loose debris / fluff from inside the pump and clean the pump. The pump impeller must be able to rotate.
Clean any residual lye or fluff from the thread of pump cap and pump housing.
Attach and tighten the pump cap.
Insert and close service flap.
To avoid unused detergent from flowing into the dra during the next wash cycle:
Pour 1litre / 1¾pt of water into chamberII.
Select the •Drain" programme.