24Care and cleaning
8. Remove foreign bodies and fluff from the filter seat and from the pump im- peller.
9.Check carefully whether the pump im-
peller rotates (it rotates jerkily). If it doesn’t rotate, please contact your Serv- ice Centre.
10. Put the cap back on the emergency emptying hose and place the latter back in its seat.
11. Replace the filter into the pump by in- serting it correctly into the special guides. Screw the pump cover firmly by turning it clockwise.
12. Refit the flap and close the pump door.
WARNING!
When the appliance is in use and depending on the programme selected there can be hot water in the pump.
Never remove the pump cover during a wash cycle, always wait until the appliance has fin- ished the cycle, and is empty. When refitting the pump cover, ensure it is securely
Cleaning the water inlet filters
If the appliance doesn't fill, it takes a long time to fill with water, the starting button blinks yellow or the display (if available) shows the relevant alarm (see chapter "What to do if..." for more details), check if the water inlet filters are blocked .
To clean the water inlet filters:
1.Turn off the water tap.
2. Unscrew the hose from the tap.
3. Clean the filter in the hose with a stiff brush.
4. Screw the hose back onto the tap. Make sure the connection is tight.