Splendide WD2100XC manual Electrical, Location, Drainage

Page 7

Electrical

Machine Voltage/Amperage - 120V, 60 Hz, 1300 W, 10.5 Amp.

Connection - 3-prong plug with 6’ cord is provided with the machine.

Circuit/Protector - 3-wire single phase, 120V, 60 Hz, AC, on a separate 15 Amp circuit.

If you have...

no access to Hot/Cold water hookups

to install a dryer vent and ducting in your RV or boat

concerns about the appliance shifting in your RV or boat

water damage concerns

to make a 90” duct turn in less than 4.5”

You’ll need...

Splendide Faucet Adapter Kit, or equivalent.

Splendide Vent Kit, or equivalent.

Splendide SecureFit bracket kit, or equivalent.

Splendide Drain-A-Way Pan, or equivalent.

Splendide 90˚ offset elbow, or equivalent.

Location

This machine may be installed free standing as well as in a recessed area, closet, or alcove

Minimum Installation Spacing - 0” on sides and 1” in front and back. NOTE: Additional installation spacing needs to be considered for easy installation, servicing, and compliance with state and federal codes.

Floor - Must support at least 280 lbs. and be a solid, level surface. DO NOT install on carpet.

RV/Marine Installations - When locating the appliance in a towable trailer or watercraft, position the machine over the axles or mid-ship where movement is at a minimum. Block the machine to prevent extreme movement.

Exhaust Requirements - Rigid or flexible metallic duct required. Ducting should be as short and straight as possible. DO NOT exhaust dryer into a chimney, furnace, cold air duct, attic crawl space, or another duct used for venting. If a cabinet door is installed, a minimum of 8 sq. in. should be provided for make up air. Louvered doors with equivalent air openings are acceptable. Allow clearances behind door(s) to avoid rubbing between back of cabinet door(s) and front of unit control panel. Additional clearances for wall, door and floor moldings may be required.

Drainage

Standpipe Diameter/Capacity - Needs a 1 ¼” minimum diameter standpipe with a minimum carry-away capacity of 7 gallons per minute.

Top of Standpipe - Must be between 25” and 34” high from the bottom of the machine.

Outlet End of Drain Hose (provided with the unit)

-Must be at least 20” above the bottom of the washer-dryer. An air break must be available at the standpipe to avoid siphoning. No more than 6” of the drain hose should be inserted into the drain pipe to prevent siphoning.

Installation requirements 7

Image 7
Contents 210oXC ContentsGeneral Information Technical information Read all instructions before using any appliance For Your SafetyFor your records CongratulationsIntroduction Read this manualElectrical Shock Hazard Installation RequirementsOutlet End of Drain Hose provided with the unit ElectricalLocation DrainageRemoving the transit screws Installing the washer-dryerConnecting the water inlets Unpacking the washer-dryerFloor Standpipe Connecting the drain hoseLeveling the washer-dryer Installing exhaust ductingTesting and cleaning the washer Completing the installationRisk of Electric Shock Do not Open About your washer-dryerDescription of the control panel Description of the Program Key Description of the Option ButtonsAbout the Dispenser Drawer Laundry Aid Type / AmountsWashing and drying Cycle Description ChartSelect the dry time Maximum Wash Cycle capacity CottonsMaximum DRY Cycle capacity 8 to 11 lbs Select the wash cycleWash cycles are 30 to 96 minutes Splendide laundry tipsFor best results Combine large and small items in one fullSample wash-to-dry loads Combo laundry FAQ’sSample Load Turning off the water or electricity supply Care and maintenanceCleaning your appliance Cleaning the dispenser drawerChecking the dryer vent Cleaning the pump pre-chamberNo lint filter to clean To access the pre-chamberUnit has entered diagnostic mode and there may be a problem TroubleshootingHours Mon-Fri 7AM-5PM PST Local Phone If you need assistance