Alliance Laundry Systems 9001014R7 Machine Foundation, Floor Load Data Model 100 135 165 200

Page 25

Basic Installation/Operation

Machine Foundation

Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation. eliminating possibilities of excessive vibration during extract.

CAUTION

Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.

W488

The washer-extractor must be placed on a smooth level surface so that the entire base of the machine is supported and rests on the mounting surface.

The standard installation does not require anchoring unless mandated by state or local codes.

Static and dynamic loads on the floor or foundation are shown in Table 2.

Table 2 can be used as a reference when designing floors and foundations.

Floor Load Data

Model

18

25

33

35

40

55

75

100

135

165

200

 

 

 

 

 

 

 

 

 

 

 

 

Kinetic Energy of

 

 

 

 

 

 

 

 

 

 

 

the Cylinder,

1386

1730

2736

3240

4105

6640

12404

18361

23257

29581

29581

(N/m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dynamic Bottom

700/16

750/16

1200/16

1200/16

1200/16

1700/15

2000/15

2960/13

3900/13

4960/13

6100/13

Load, (N/Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2

 

 

 

 

 

 

9001014

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

23

Image 25
Contents Washer-Extractors Page Contents Model Identification IntroductionExplanation of Safety Messages Safety InformationImportant Safety Instructions Basic Installation/Operation Safety Decals Operator Safety General Specifications Model Overall Dimensions Specifications and DimensionsWeight and Shipping Information Wash Cylinder InformationCentrifugal Force Data Cylinder SpeedsBalance Detection Direct Steam Heating OptionalWeight and Shipping Information RPM 18 560 mm 660 mm Hot Water Inlet Required Model Flushing Supply Dispenser Steam Connection Input Optional 82 mm 860 mm 33.86 916 mm 36.06 332 mm 13.05 50 mm 34 mm 765 mm 30.12 780 mm 30.71 833 mm 32.8 External Liquid Supply Inlets 488 mm 41.73 19.2 960 mm 100 1010 mm 360 mm 273 mm 14.25 1185 mm 56.5 mm Recommended Minimum Clearances Model 100 135 165 200 InstallationFloor Load Data Model 100 135 165 200 Machine FoundationMechanical Installation 898 mm 1300 mm 33 mm 51.2 1251 mm 1185 mm 46.7 Mounting Bolt Installation If Required Electrical Specifications Voltage Designation Electrical SpecificationsElectric Heat Code Control Identification OperationLoad the Machine Disposal of Unit