Alliance Laundry Systems 9001014R7 manual Operator Safety

Page 8

Basic Installation/Operation

Operator Safety

WARNING

NEVER insert hands or objects into basket until it has completely stopped. Doing so could result in serious injury.

SW012

To ensure the safety of machine operators, the following maintenance checks must be performed daily:

1.Prior to operating the machine, verify that all warning signs are present and legible. Missing or illegible signs must be replaced immediately. Make certain that spares are available.

2.Check door interlock before starting operation of the machine:

a.Attempt to start the machine with the door open. The machine should not start with the door open.

b.Close the door without locking it and attempt to

start the machine. The machine should not start with the door unlocked.

c.Close and lock the door and start a cycle. Attempt to open the door while the cycle is in progress. The door should not open.

If the door lock and interlock are not functioning properly, call a service technician.

3.Do not attempt to operate the machine if any of the following conditions are present:

a.The door does not remain securely locked during the entire cycle.

b.Excessively high water level is evident.

c.Machine is not connected to a properly grounded circuit.

Do not bypass any safety devices in the machine.

WARNING

Never operate the machine with a bypassed or disconnected balance system. Operating the machine with severe out-of-balance loads could result in personal injury and serious equipment damage.

SW039

6

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9001014

Image 8
Contents Washer-Extractors Page Contents Introduction Model IdentificationImportant Safety Instructions Safety InformationExplanation of Safety Messages Basic Installation/Operation Safety Decals Operator Safety Specifications and Dimensions General Specifications Model Overall DimensionsWeight and Shipping Information Wash Cylinder InformationCylinder Speeds Centrifugal Force DataBalance Detection Direct Steam Heating OptionalWeight and Shipping Information RPM 18 560 mm 660 mm Hot Water Inlet Required Model Flushing Supply Dispenser Steam Connection Input Optional 82 mm 860 mm 33.86 916 mm 36.06 332 mm 13.05 50 mm 34 mm 765 mm 30.12 780 mm 30.71 833 mm 32.8 External Liquid Supply Inlets 488 mm 41.73 19.2 960 mm 100 1010 mm 360 mm 273 mm 14.25 1185 mm 56.5 mm Installation Recommended Minimum Clearances Model 100 135 165 200Machine Foundation Floor Load Data Model 100 135 165 200Mechanical Installation 898 mm 1300 mm 33 mm 51.2 1251 mm 1185 mm 46.7 Mounting Bolt Installation If Required Electric Heat Electrical SpecificationsElectrical Specifications Voltage Designation Code Operation Control IdentificationLoad the Machine Disposal of Unit