IPSO TMB1268C Specifications and Dimensions, Specifications Pound, Gas Models, Steam Models

Page 5

 

 

Tumblers – 120 and 170

Specifications and Dimensions

 

 

 

 

 

Specifications

120 Pound

170 Pound

 

 

 

Noise level measured during operation

66 dBA

66 dBA

at operator position of 3.3 feet (1 meter)

 

 

in front of machine and 5.2 feet

 

 

(1.6 meters) from floor.

 

 

 

 

 

Cylinder Size:

44 x 41

50.75 x 42.5

Inches (mm)

(1118 x 1041)

(1289 x 1080)

 

 

 

Cylinder Capacity dry weight:

120

170

Pounds (kg)

(54.4)

(77.1)

 

 

 

Cylinder Motor Horsepower

0.75

0.75

 

 

 

Fan Motor Horsepower

1

3

 

 

 

Air Outlet Diameter:

10

12

Inches (mm)

(254)

(300)

 

 

 

Maximum Static Back Pressure:

0.3

0.3

W.C.I. (mbar)

(0.8)

(0.8)

 

 

 

Maximum Airflow:

1600

2450

C.F.M (L/sec.)

(755)

(1156)

 

 

 

 

Gas Models

 

 

 

 

Net Weight (approximate):

1275

1575

Pounds (kg)

(580)

(716)

 

 

 

Gas Connection

3/4 in. NPT

1 in. NPT

 

 

 

Gas Burner Rating:

270,000

395,000

Btu/hr. (Mj/hr.)

(285)

(421)

 

 

 

 

Steam Models

 

 

 

 

Net Weight (approximate):

1375

1675

Pounds (kg)

(625)

(761)

 

 

 

Steam Connection

3/4 in. NPT inlet

3/4 in. NPT inlet

3/4 in. NPT outlet

1 in. NPT outlet

 

 

 

 

Steam Coil Rating at 100 psig:

11.7

18.8

Boiler Horsepower (Btu/hr.)

(405,000)

(648,000)

(recommended operating pressure

 

 

80-100 psig)

 

 

 

 

 

3-09-71

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

4

Image 5
Contents On-Premise Laundry Planning Handbook Contents Gas Steam/Thermal Oil Pound IntroductionModel Identification Conversion Table Multiply To Obtain Tumblers 120Specifications Pound Specifications and DimensionsGas Models Steam ModelsCabinet Dimensions Models 120L/N Pound Tumbler Dimensions and Exhaust Outlet LocationsExhaust Outlet Dimensions and Locations Models 120L/N 120SExhaust Outlet Dimensions and Locations Models 170L/N/S Pound Tumbler Dimensions Exhaust Outlet LocationsCabinet Dimensions Models 170L/N/S 170L/N Electric and Gas Connection Locations for Gas ModelsModels Electrical Connection Gas Connection Models Electrical Connection Electric and Steam Connection Locations for Steam Models170S Pre-Installation Inspection InstallationTumbler Enclosure Layout Exhaust RequirementsMake-Up Air VentingDuct Equivalent Length Diameter Rigid Straight Duct Individual VentingTMB2103N Manifold Venting Mm Duct Duct PoundTWO Manifold Assemblies Duct Pound Station Mm DuctElectrical Requirements