Alternate exhaust methods

To remove the power supply cord -

Disconnect power supply.

7

When local codes.. .

A n

The washer/dryer mstallad in a mobile home must be exhausted JutsIde. When the dryer IS exhausted through the floor, the :xhaust system must termmate Jutside the enclosed area under noblIe home. Extension beyond the enclosure will prevent lint and noisture buildup under the mobile Tome. See Figure 3.

Mobile home installation

Alternate electrical connection

Electrical ground is required on this appliance.

This appliance is manufactured with the neutral terminal connected to the frame.

To connect a separate grounding wire -

Use grounding wire and clamp assembly (Part No. 665463) or No. 10 gauge minimum copper grounding wire. Connect grounding wire to a grounded cold water pipe’ with the clamp and then to the external grounding connector on washer/dryer. Do not ground to

a gas sup$y pipe. Do not connect the Dower SUDDIVcord to electric power supplj ;itil appliance Is permanently grounded.

No. A

Figure 4

Grounded cold water pipe must have metal continuity to electrical ground and not be Interrupted by plastic, rubber or other electrlcal Insulating connectors such as hoses, finings, washer or gaskets (including water meter or pump). Any electrical insulating connector should be jumped as shown In Figure 4 with a length of No. 4 wire securely clamped to bare metal at both ends.

4NEL F

1, Remove the terminal block cover from the dryer.

2.Disconnect the power supply cord from the termmal block.

3.Use a screwdnver to slide the strain rehe( clip away from the power supply cord. (See Figure 5)

4.Pull downward on the power supply cord until it IS removed from the dryer.

away trdm

Figure 5 power supply cord.

Pull out power supply cord.

Toconnect

Plain wire ends -

I. Strip outer covering back 3 inches irom the end exposing the 3 wires.

2.Strip the insulation back 1 inch from the end of each wire. Form the Dare wire into a “U”shaped hook.

3.Loosen, do not remove, screws from terminal block. Attach wires according to instrucflons for type of :onnection needed.

1.Slide the end of each wire under the screw head with the ooen &de si the hook on the right.. Sbueeze the wire together to form a loop.

5. Tighten each screw firmly.

Ptaln-end field wiring

Figure 6

To use non-metallic sheathed copper power suppfy cabfe -

CAUTION: If non-metallic sheathed copper power supply cable is used, it must be used with a U.L. recognized strain relief (U L. mark on it or KitchenAid Part No. 667000) to fit a one Inch hole size similar to the one shown In Figure 7.

Figure 7

Permit use 01flexible type power supply cord (pigtail) that comes equipped with the washer/dryer but

Do Not Permit connecting the frame grounding conductor to the neutral wire of the power supply cord:

1.Remove terminal block cover.

2.Remove the grounding wire (green) from the internal grounding connector and fasten under center sliver-coated terminal block screw. See Figure 6.

3.Connect a separate copper grounding wire (No. 10 minimum). See “Toconnect a separate grounding wire:’ Panel F for detallec instructlone

4.Replace terminal block cover.

Image 7
Contents Laundry Center Supply Cord ALL Governing CodesSee NemaUse Duct Tape to peal all joints Four Inch Metal Exhaust Duct isPanel B Shlpplng Strap with key Numbers correspondPanel C Panel D Lo openFll Move washer/dryer closeNEL E CongratulationsAlternate electrical connection Alternate exhaust methods4NEL F Neutral Replace the terminal block coverPanel G Replace lermitw Mock cover Cold Wster Inlet Recess Width Recessedarea hlstructionsPrepared by KitchenAid, Sl. Joseph, Michigan