installing your dryer
6.Review Gas Requirements section. Remove the pipe thread protective cap.
Apply pipe joint compound or about 1 1/2 wraps of Tefl on tape over all threaded connections. Pipe joint compound must be resistant to the action of any liquefi ed petroleum gas.
Connect the gas supply to your dryer.
An additional fi tting is required to connect the 3/4” (1.9 cm) female thread end of a fl exible connector to the 3/8” (1 cm) male threaded end on the dryer.
Securely tighten the gas line fi tting over threads.
Turn on the gas supply. Check all gas connections for leaks using a soap solution. If bubbles appear, tighten the connections and recheck.
DO NOT use an open fl ame to check for gas leaks.
3-WIRE system connections
1.Loosen or remove the center terminal block screw.
2. Connect the neutral wire (white or center wire) of the power cord to the center,
3. Connect the other wires to outer terminal block screws. Tighten screws.
4.Tighten the strain relief screws.
5.Insert the tab of the terminal block cover into your dryer’s rear panel slot.
Secure the cover with a
1.External ground connector
2.Neutral grounding wire (green/yellow)
3.Center
4.Neutral wire (white or center wire)
5.3/4” (1.9 cm)
If converting from a
conductor.
20_ installing your dryer