Maytag MLG-45PDB Installation Procedures, Location Requirements, Leveling Dryer, Tools Required

Page 6

Installation Procedures _______________

! WARNING

Excessive Weight Hazard

Use two or more people and mechanical equipment to lift, move and install dryer.

Failure to do so can result in back or other injury.

Installation should be performed by competent professional in accordance with local, state, and country codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1-LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70- LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/ CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections).

Leveling Dryer

The dryer is equipped with 4 leveling legs, 1 at each corner of the base. For optimum performance the dryer should be level front-to-back and side-to-side.

Tools Required

Utility Knife to remove packaging

9/16” Box wrench or 9/16” socket to remove pallet bolts

#2 Phillips screwdriver to open box cover

Pipe wrench for gas connections

7/8” open end wrench or adjustable wrench to install coin box lock

Leveling feet adjustment

TORX® T20 TORX® T25 to open front and rear to get foot adjustment ends

1/4” socket or 1/4” open end wrench to make the adjustment

®TORX is a registered trademark of Textron Innovations, Inc.

Location Requirements _______________

! WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Do not install in a garage.

Failure to do so can result in death, explosion, or fire.

Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing).

The operation of this dryer may affect the operation of other types of gas dryers, which take their air for safe combustion from the same room. If in doubt, consult the dryer manufacturer(s).

The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on.

Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply Requirements section).

Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer Enclosure Requirements section).

Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements section).

The dryer must be installed with a proper exhaust duct connection to the outside as noted in this manual (refer to Exhaust Requirements section).

The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements section).

IMPORTANT: The dryer should be located where a minimum amount of exhaust ducting will be necessary.

The dryer must be installed with adequate clearance for air openings into the combustion chamber.

IMPORTANT: The dryer must be installed in a location/ environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C).

6

Maytag Co.

113489 - 3 (W10185535)

Image 6
Contents MLG-45PDB Installation Manual Dryer Safety Your safety and the safety of others are very importantImportant Safety Instructions Table of Contents Specifications Leveling Dryer Installation ProceduresLocation Requirements Tools RequiredDryer Enclosure Requirements Fresh Air Supply RequirementsExhaust Requirements Outside Ductwork Protection Single Dryer Venting with Transition PieceSingle Dryer Venting without Transition Piece Multiple Dryer Common VentingElectrical Information Gas Information Type of GasPreparation for Operation/Start-Up Gas ConnectionsPiping/Connections Preoperational Test Service/Parts InformationRoutine Maintenance Operating InstructionsData Label Information