Part 3 INITIAL STEPS FOR INSTALLING YOUR DRYER

STEP 4: Connection of Gas Supply

(Gas dryer only). In addition to the following, please refer to manual section on Gas Requirements and Instructions.

1

2

5

3

4

1.New stainless steel flexible connector. Use this type of connector only if allowed by local codes. Use Design AGA Certified Connector.

2.1/8" NPT Pipe Plug (for checking inlet gas pressure)

3.Equipment Shut-Off Valve- Installed within 6’ (1.8 m) of dryer

4.Iron Pipe. Shorter than 20’ (6.1 m)

Use 3/8" pipe. Longer than 20’ (6.1 m) - Use 1/2" pipe.

5.3/8" N.P.T. Gas Connection

1.Confirm that the type of gas available in your laundry room is appropriate for the dryer. The dryer is prepared for Natural Gas with a 3/8"

NPT gas connection.

2.Remove the shipping cap from the gas connection at the back of the dryer. Make sure that you don’t damage the threads of the gas connection pipe when you remove the shipping cap.

3.Connect the dryer to your laundry room’s gas supply using a new flexible stainless steel connector (as noted below, only use a new stainless steel flexible connector if allowed by your local codes).

4.Securely tighten all connections between the dryer and your laundry room’s gas supply. Turn on your laundry room’s gas supply and check all pipe connections (both internal and external) for gas leaks with a non-corrosive leak detection fluid.

5.For LP (Liquefied Petroleum) gas connection, refer to this manual’s section entitled Gas Requirements and Instructions.

STEP 5: Electrical Plug Connections for Electric Dryer Only.

Following are several warnings and instructions concerning making the electrical connection for electric dryers. More detailed information concerning the electrical connection is provided at the manual section entitled Electrical Requirements For Electric Dryer and it is important that you thoroughly review that section, and the remainder of this manual, before taking any steps to install or use this dryer.

1.Use only a new U.L. listed No. 10 (copper wire only) three conductor power supply cord kit rated 240 Volts (minimum) 30 Amperes and labeled as suitable for use in a clothes dryer.

2.Four-wire cord is required for manufactured (mobile) home installations and use and where local codes do not allow grounding of this appliance through neutral.

3.The wiring diagram is provided inside the dryer control hood. Label all wires prior to disconnection when servicing the dryer, because wiring errors can cause serious injury to you and your dryer.

4.For additional instruction on connecting the dryer to an electrical power source, please refer to this manual’s section on Electrical Requirements and Electric Dryer.

!WARNING!

Use a new UL approved 30 amp power supply cord or 10 gauge solid copper wire.

Use a UL approved strain relief.

Disconnect power before making electrical connections.

Connect neutral wire(white or center wire) to center terminal.

Ground wire(green or bare wire) must be connected to green ground connector.

Securely tighten all electrical connections

See installation instructions for complete instructions.

Failure to do so can result in fire or electrical shock.

1 0

Image 10
Contents Electric and Gas Dryer Table of Contents Part 1 Specifications Part 2 Important Warranty and Safety Instructions Seeking Warranty AssistanceImportant Safety Instructions What to do if YOU Smell GAS California safe drinking water and toxic enforcement actPart 3 Initial Steps for Installing Your Dryer Positioning the DryerProcedure for Reversing the Door Connecting the Exhaust and Venting System Clean old ducts before installing this dryerConnection of Gas Supply Electrical Plug Connections for Electric Dryer OnlyDryer Airflow Preparation of the DryerConfirming Heat Source Operation Confirming Heat Source in Gas DryersPart 3 Initial Steps for Installing Your Dryer Part 4 Electrical Requirements for Electric Dryers Instructions for Grounding of your Electric Electric DryerWire receptacle Nema type10-30R Wire directWire connection Direct wire Wire receptacle Nema type14-30RPart 4 Electrical Requirements for Electric Dryers Option 1 3-Wire Connection with a Power Supply Cord Wire connectionOption 2 4-wire connection with a Power supply cord Option 3 Optional 3-wire connection Volt, 60 Hertz, with 3-Prong Grounding Plug Part 5 Electrical Requirements for GAS DryersElectrical Requirements for Your Dryer Part 6 GAS Requirements and Instructions Part 7 Exhaust Requirements and Maintenance Exhaust Requirements and InstructionsExhaust and Dryer Maintenance Cleaning the Lint ScreenExplosion Hazard Using Your DryerPart 8 Operating Your Dryer Fire HazardStopping Your Dryer Pausing or RestartingTo use a Sensor Dry Cycle To use a Manual Dry CycleSensor Dry Temp Time Cycles Load Type Cycle DescriptionsChild Lock Sensor Dry CycleOptions ModifiersAnti Bacterial Rack DryTo use the Rack DRY To store a Custom Clean the door and its openingCustom Programming Beeper To recall your stored Custom ProgramPart 9 Troubleshooting Guide Question What to DoProblemThere is Lint on my Clothes ProblemIt takes too long for my clothes to dry LG Dryer Limited Warranty USA