Part 4 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS
4.Put the hooked shape ends of the wire under the screw of the terminal block(hooked end facing rightward) and squeeze the hook together and screw tightly.
5.Put the hooked shaped ends of the other power supply cable wires under the outer terminal block screws(hooked end facing right) and squeeze the hooked ends together and screw tightly.
6.Tighten strain relief screws.
7.Place the tab of terminal block cover into slot of dryer rear panel. Make sure cover with screw.
3-wire connection : Direct wire
Important : The places wherea
At least, 5ft(1.52m) of extra length is required for dryer to be able to move.
Peel 5 in (12.7cm) of external covering from end
of cable, leaving bare ground wire at 5 in (12.7cm). Cut 11/2 in. (3.8cm) from 3 remaining wires. Strip insulation back 1in. (2.5cm). Shape ends of wires into a hook shape.
" | |
1 | cm) |
| |
.5 | |
(2 |
|
2" |
|
3V |
|
.9 cm) | |
(8 |
|
Then, put the hooked shape end of the wire under the screw of the terminal block(hooked end facing rightward) and pinch the hook together and screw tightly.
1.Take off center terminal block screw
2.Put the hooked end of the neutral wire(white) of power supply cable under the center screw of terminal block). Squeeze the hooked end together
3.Connect the hooked ends of the other power supply cable to the center screw of terminal block.
4.Screw strain relief tightly.
5.Place tab of terminal block cover into slot of dryer rear panel. Make sure cover with screw.
| c |
| b |
| d |
a | e |
|
a.External ground connector
b.Neutral grounding wire (white)
c.Center
d.Neutral wire (white or center wire)
e.3/4 in. (1.9 cm)