Fisher & Paykel DGGX1US installation instructions Exhaust venting, Fire Hazard

Page 14

Exhaust venting

WARNING

Fire Hazard

Use heavy metal exhaust duct.

Do not use a plastic exhaust duct.

Do not use thin metal foil exhaust duct.

Failure to do so can result in death or fire.

1.Read the exhaust section (page 9–13) before installing the exhaust system to determine the maximum allowable exhaust duct length.

Do not use sheet metal screws when assembling ducting. Always use suitable duct tape. Never use plastic or thin metal foil flexible exhaust material.

2.The exhaust outlet is located close to the center of the rear of the dryer. Make sure you join the exhaust duct to the dryer with duct tape only. This will prevent lint and dust from escaping from the dryer and exhaust system.

Exhaust outlet

 

4

(111mm)

 

"

 

 

8

 

 

3/

 

13 7/8" (352mm)

13 1/8" (333mm)

 

3.The exhaust vent can be routed up, down, left, right or straight out the back of the dryer. Refer to diagram.

14

Image 14
Contents Installation instructions DGGX1USWhat to do if you smell gas Important safety instructions Tools required Read this before you start installing your dryerAccessories Parts suppliedExplosion Hazard To the installerLocation requirements Alcove or closet installation Exhaust outlet location DimensionsLid clearance Mobile home installation Exhausting Fire HazardDetermine vent duct length Maximum length of exhaust duct Preferred 4 Hoods Alternative installation for close clearances Exhaust venting Unpacking InstallationExcess Weight Hazard Remove packagingFitting the front feet Grounding instructions Electrical requirementsElectrical Shock Hazard Natural Gas Gas requirementsGas type LP Gas conversionGas ignition Connecting gas to your dryerConnecting to the gas supply Connecting to the dryer Completing the connectionFinal installation check list Level machinePage Page Installation Instructions Published 03/2004 Part No a