Fisher & Paykel DGGX1US To the installer, Location requirements, Explosion Hazard

Page 5

To the installer

The correct installation of the dryer is your responsibility.

Be sure you read the following instructions carefully before you start to install the dryer. These instructions should be left with the home owner for future reference.

It is your responsibility to:

Observe all governing codes and ordinances.

Check code requirements. Some codes limit or do not permit installation of clothes dryers in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

Adhere to these installation instructions.

Allow for spacing requirements with side by side installations (refer page 6).

Make sure you have all items necessary for correct installation.

Properly install the dryer.

Contact a qualified installer to ensure that the electrical and gas installation meets all national and local codes and ordinances.

Location requirements

WARNING

Explosion Hazard

Keep flammable materials and vapours, such as gasoline, away from the dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, fire, or burns.

The dryer must be installed or stored in an area which is not exposed to water or weather.

It is extremely important that the dryer is installed in a well ventilated location. This dryer must exhaust air outdoors. Do not install the dryer in any room or closet which does not permit the free flow of replacement air.

Before installing the dryer ensure that there is sufficient height to fully open the lid. Allow sufficient room behind the dryer for the exhaust. The air intake is at the rear of the dryer. Ensure that there is a sufficient air passage on each side of the dryer for intake air.

5

Image 5
Contents DGGX1US Installation instructions What to do if you smell gas Important safety instructions Accessories Read this before you start installing your dryerTools required Parts suppliedExplosion Hazard To the installerLocation requirements Alcove or closet installation Exhaust outlet location DimensionsLid clearance Mobile home installation Fire Hazard ExhaustingDetermine vent duct length Maximum length of exhaust duct Preferred 4 Hoods Alternative installation for close clearances Exhaust venting Excess Weight Hazard InstallationUnpacking Remove packagingFitting the front feet Grounding instructions Electrical requirementsElectrical Shock Hazard Gas type Gas requirementsNatural Gas LP Gas conversionGas ignition Connecting gas to your dryerConnecting to the gas supply Completing the connection Connecting to the dryerLevel machine Final installation check listPage Page Installation Instructions Published 03/2004 Part No a