Heatcraft Refrigeration Products 2500018 warranty Vertical Condenser, Horizontal Condenser

Page 4

Installation and Operations Manual

Vertical Condenser

Vertical airflow units should be located no closer than the width of the unit from a wall or other obstruction. If two or more units are to be positioned in the same area, a similar distance should be maintained between adjacent units. Sufficient free area should be left around and below unit to avoid air restriction to coil.

Leg Assembly for Vertical Airflow Installation (Models 008-016; 1-3)

Figure 3. Leg assembly (vertical airflow, models 008-016; 1-3)

1.Assemble the unit’s two legs (Figure 3, item 2) using three 1/4 - 20 x 3/4” long bolts per leg. Captive nuts are provided on unit for this assembly.

. Four gussets (Figure 3, item 3) are provided for leg support.

3.Assemble the gusset in each corner with 1/4 - 20 x 3/4”long bolts and 1/4” nuts.

4.Discard the four mounting angles (Figure 5, item 1).

Leg Assembly for Vertical Airflow Installation (Models 024-133; 5-26)

Figure 4. Leg assembly (vertical airflow, models 024-133; 5-26)

1. Remove fasteners securing condenser to skid.

. Remove leg extensions (Figure 4, item 1) by removing four 5/16” x 3-1/2” bolts.

3.Install as shown in dotted lines with same four bolts.

4.Install mounting angle (item 2) as shown (dotted lines) with four 1/4 - 20 x 3/4” bolts provided.

5.Condenser can be hoisted by attaching hooks into 1-1/2” holes in leg assemblies.

Horizontal Condenser

Horizontal airflow units should be installed with the coil (inlet air side) facing the prevailing winds. Where strong winds are common, it is recommended that a wind deflector (not supplied) be used to discharge the air vertically from the unit, to prevent capacity loss during varying wind conditions. The wind deflector should be installed on the fan side of the unit.

If horizontal airflow units are installed with the air inlet facing a wall, a distance of at least 48 inches should be maintained between unit and wall. If it is necessary to have the unit positioned so the air discharge is toward a wall, it should be spaced at a distance no less than three times the coil face height from the wall.

Leg Assembly for Horizontal Airflow Installation (Models 008-016; 1-3)

Figure 5. Leg assembly (horizontal airflow, models 008-016 ; 1-3)

1.Attach four mounting angles (Figure 5, item 1) to the unit, using two 1/4 - 20 x 3/4” long bolts and 1/4” nuts per mounting angle.

. Discard the two legs, (Figure 3, item 2) and four gussets (Figure 3, item 3).

Part # 2500018

Image 4
Contents Installation and Operations Manual Installation Requirements InspectionRigging and Moving Units Unit LocationRemote Air-Cooled Condenser Space and Location RequirementsHorizontal Condenser Vertical Condenser2500018 Installation, Refrigerant Piping Typical Piping ArrangementsElectrical Wiring Condensing Temperature Correction FactorTons of Refrigeration, Discharge Tons of Refrigeration, DrainT1 T2 Start Up OperationCleaning Instructions MaintenanceFlooded Head Pressure Control Valve FHP FHP Charge Factor T.D and 30 ˚F Refrigerant Charge, R-22 lbsSystem Warranty In-Warranty Return Material ProcedureCondenser Specifications SpecificationsDiagram 6. Dimensions for Models 008-016 General Fan Layouts37 1/2 Replacement Parts by Replacement Parts ListModel Motors Fan Quantity 230/1/60 230/460/3/60Installation Checklist Climate Control

2500018 specifications

Heatcraft Refrigeration Products has established itself as a leader in the refrigeration industry, offering innovative solutions designed to meet the diverse needs of commercial and industrial applications. One of their notable offerings is the Heatcraft Refrigeration Products 2500018, a high-performance refrigeration unit that combines reliability, efficiency, and advanced technology.

The Heatcraft Refrigeration Products 2500018 is specifically engineered for various cooling applications, making it suitable for a wide range of setups, including foodservice establishments, cold storage facilities, and supermarkets. Its robust construction ensures durability, which is crucial for environments that require constant refrigeration.

One of the main features of the 2500018 is its energy efficiency. Designed to minimize energy consumption while maximizing cooling performance, this model adheres to the latest industry standards for energy efficiency. This is particularly important for businesses seeking to reduce operational costs and improve their environmental footprint. The unit employs advanced insulation technology, ensuring minimal energy loss and maintaining optimal temperatures inside.

The 2500018 incorporates cutting-edge technology that enhances its functionality. It features a user-friendly digital controller that allows for precise temperature management, enabling operators to set and monitor conditions with ease. Additionally, the system includes various safety mechanisms, such as pressure controls and temperature alarms, which provide peace of mind by preventing operational failures and ensuring the safety of stored products.

Another significant characteristic of the Heatcraft 2500018 is its versatility. The unit can be tailored to meet specific application requirements, thanks to its customizable options. This adaptability makes it a preferred choice among business owners who need reliable refrigeration solutions that fit their unique operational needs.

Moreover, the sleek design and compact size of the 2500018 make it an excellent choice for space-constrained environments. Its installation is straightforward, and it’s designed for easy maintenance, allowing technicians to perform service tasks efficiently.

In summary, the Heatcraft Refrigeration Products 2500018 stands out as an exceptional refrigeration solution due to its energy efficiency, advanced technology, versatility, and ease of maintenance. With a commitment to quality and innovation, Heatcraft continues to set the industry standard, addressing the ever-evolving demands of commercial refrigeration. Businesses that invest in the 2500018 can expect uncompromised performance and reliability, ensuring their refrigeration needs are met effectively.