3-4 Setup Procedures

3-4 Setup Procedures

This section provides the procedures necessary for configuring your Dehumidifying Dryer.

Configuration of your dryer includes checking for proper blower rotation, making dryer/drying hopper process air connections and the optional aftercooler (on 15 and 30 cfm models). We recommend that you carry out these procedures in the order given here.

Note: Before carrying out these procedures, install all equipment as described in this section.

Checking for Proper Blower Rotation

Three-Phase Models

Caution! In three-phase models, incorrect phasing of power leads can cause backward rotation of blower motors and CONTAMINATION OF THE DESICCANT!

Always check blower rotation before putting material in the drying hopper!

The blower is rotating properly when air flows from the delivery outlet.

Note: Holding your hand in front of the air return will also indicate if the blower rotates in the proper direction.

If the three-phase blower rotates improperly, reverse any two wires at the fused disconnect outside the dryer or at the disconnect/terminal in the control enclosure. This assures that the blower rotates in the proper direction.

Making Dryer/Drying Hopper Process Air Connections

Floor Mount Models

When making process air connections to your floor mounted dryer, ensure that you take into consideration and make arrangements for the following:

Use high-temperature flexible dryer hose or rigid tubing to connect the dryer to the drying hopper.

Keep the delivery hose to the drying hopper as short as possible to minimize heat loss. We strongly recommend insulated hose for maximum energy savings.

Do not use insulated hose on the return from the drying hopper.

The return air to the blower must be 150°F (66ºC) or below. If the return air temperature is not below this point, you should purchase and install the optional aftercooler to remove excessive heat. Consult the manufacturer for more information. Aftercooler considerations also apply to machine-mount models.

Make sure that hoses are not kinked or collapsed.

Drying hopper air inlet and outlet locations vary, but always connect hoses so the dry process air from the dryer enters the bottom of the drying hopper and flows out the top to return to the dryer inlet.

Thermocouple is to be installed at drying hopper’s delivery tube.

15, 30, & 60 cfm Compact Dryers

17

Image 17
Contents SDA Series 15-60cfm Compact Dehumidifying Dryers Unpacking and Inspection Shipping InformationIn the Event of Shipping Damage If the Shipment is Not CompleteCHAPTER 3: INSTALLATION Table of ContentsCHAPTER 1: SAFETY CHAPTER 2: FUNCTIONAL DESCRIPTIONCHAPTER 6: TROUBLESHOOTING CHAPTER 5: MAINTENANCECHAPTER 7: APPENDIX 15, 30, & 60 cfm Compact DryersSafety Symbols Used in this Manual Chapter 1 Safety1-1How to Use This Manual 1-3Warnings and Precautions 1-2Safety Tag InformationRead Operation and Installation Manual Dryer Safety TagsOperator Responsibility 1-4ResponsibilityGeneral Responsibility REMEMBER Reporting a Safety Defect Maintenance Responsibility2-1Models Covered in This Manual Chapter 2: Functional Description2-2General Description What is desiccant?Figure 1: Typical Dryer Air Flow Schematic 2-3Standard FeaturesMechanical Features Electrical FeaturesController Features 2-5Safety Devices and Interlocks2-4Options Fail Safe Operation Safety Circuit StandardsSafety Device Lock-Outs 3-2Rigging and Placing the Dryer Chapter 3: Installation3-1Uncrating the Equipment DEW POINT POWER ON15, 30, & 60 cfm Compact Dryers 3-3Electrical Connections Three-PhaseModels 3-4Setup ProceduresChecking for Proper Blower Rotation Floor Mount ModelsInstalling Water Lines 3-5Initial Start-upDrying Hopper Air Trap Considerations Optional AftercoolerShutting Down the Dryer Auto-Tuningthe Dryer4-1Controller Description and Operation Chapter 4: OperationSwitches Indicator LightsPV SV Process Air Temperature ControllerLit when Control Output 1 is on. The Out1 IndicatorLit when Control Output 2 is on. Not used in IndicatorIndicator Setting the Process Air TemperatureAdjustment Level IndicatorName IndicatorDescription Entering Operating Parameters to Select ModesOptional Setting the High Dew Point AlarmProcess Air Dew Point Display Controller Operation 4-2Dryer Operation ProceduresAlarm Display Messages HEAT COOL 50 SYSTEM NORMAL HIGH TEMP VALVE MTRValve Motor Time-Out Blower Overload No Alarms PROC BLWR5-1Preventative Maintenance Schedule Chapter 5: MaintenanceEvery Day Every weekFigure 9 Air Filter Location and Disassembly 5-2Preventative MaintenanceServicing Process Air Filters VacuumingCleaning with Compressed Air 5-3Corrective MaintenanceSymptoms of Worn Desiccant Servicing the Dew Point MonitorReplacing Worn Desiccant + FIRST AID +Figure 11: Required Desiccant Amounts 13X Type Figure 10: Desiccant Bed Location and DisassemblyWARNING! Hazardous electrical current present ProceduresReplacing the Process/Regeneration Heater Figure 13: Cooling Coil Location and Disassembly Replacing/Cleaning the Cooling CoilReplacement Procedures If used as an after-Cooler:3 to 4 GPM @ 85F15, 30, & 60 cfm Compact Dryers 8.Inset the four 10-32bolts back in place9.Turn the water to the cooling coil back on HIGH TEMP Chapter 6: Troubleshooting6-1Introduction Alarm Message PROC BLWRHIGH TEMP CauseUsing a Thermocouple VALVE MTRAlarm Message CauseChapter 7: Appendix 7-1WarrantyWarranty Specifications Warranty RestrictionsAnnex B Information 7-2Technical SpecificationsCustomer Responsibilities Aftercooler Design Specifications 7-3Drawings and DiagramsRegeneration MoistureMake Up Air Exhaust High Pressure Peripheral BlowerAfter-Cooler Regeneration MoistureMake Up Air Figure 16: Low Heat Model 120F to 250F Air FlowExhaust High Pressure Peripheral BlowerDRYER SPARE PARTS LIST 15, 30, 60 cfm Models 7-4Spare Parts List15, 30, & 60 cfm Compact Dryers Mechanical ComponentsHI-COREDESICCANT DRYER 15/30/60 CFM UNITS 15, 30, & 60 cfm Compact Dryers30 CFM 15, 30, & 60 cfm Compact DryersPart # Description60 CFM 15, 30, & 60 cfm Compact DryersItem Part #A0571672 15, 30, & 60 cfm Compact Dryers120V CONTROL COMMON PARTS ItemCredit Returns 7-5Returned Material Policy7-7Technical Assistance 7-6Dryer Identification Serial Number TagWarranty Returns Service DepartmentSales and Contracting Department Parts and Service Department15, 30, & 60 cfm Compact Dryers Contract Department
Related manuals
Manual 50 pages 20.38 Kb Manual 51 pages 45.86 Kb

882.00291.00 specifications

Sterling 882.00291.00 is a remarkable piece of technology designed to cater to the rigorous demands of modern users who require both utility and aesthetics in their devices. This innovative product is a testament to Sterling's commitment to quality and functionality, combining advanced features with user-friendly designs to enhance the overall experience.

At the heart of the Sterling 882.00291.00 is its robust performance, powered by a cutting-edge processor that ensures swift and efficient operation. Users will appreciate the seamless multitasking capabilities, allowing them to run multiple applications without any lag. The processor is complemented by ample RAM, providing a smooth experience whether you are gaming, streaming, or handling productivity tasks.

One of the standout features of the Sterling 882.00291.00 is its high-resolution display. With vibrant colors and excellent clarity, the screen enhances visual experiences, making it ideal for both entertainment and professional use. Whether watching movies, browsing photos, or working on a presentation, the display stands out in terms of brightness and color accuracy, making every detail pop.

Connectivity is another strong suit of this model. Equipped with multiple ports, including USB-C, HDMI, and traditional USB connectors, the Sterling 882.00291.00 ensures users can connect to a wide array of peripherals and external devices with ease. Furthermore, the inclusion of Bluetooth and Wi-Fi capabilities facilitates quick and reliable wireless connections, making it a versatile choice for those on the go.

Durability is a crucial characteristic that sets the Sterling 882.00291.00 apart from its competitors. The device features a sturdy build quality that can withstand daily wear and tear, making it suitable for both personal and professional environments. Additionally, the device is designed with energy efficiency in mind, offering an extended battery life that supports prolonged use without frequent recharging.

In terms of software, the Sterling 882.00291.00 comes equipped with an intuitive operating system that simplifies navigation and enhances user engagement. The user interface is designed to be accessible, allowing individuals of varying tech-savvy levels to operate the device comfortably. Regular updates ensure that users have access to the latest features and security protections.

In conclusion, the Sterling 882.00291.00 stands out for its blend of performance, connectivity, and durability. With its high-resolution display, robust processor, and thoughtful design, it serves as a reliable companion for anyone looking to enhance their digital experience. Whether for work or play, this device positions itself as a go-to option for those seeking quality and reliability.