American Dryer Corp MDG50V installation manual Fresh AIR Supply Requirements

Page 15

D. FRESH AIR SUPPLY REQUIREMENTS

The air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An unrestricted source of air is necessary for each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1-1/2 square feet (0.14 square meters) is required for each dryer. If registers or louvers are installed over the openings, then the area must be increased. It is not necessary to have separate make-up air openings for each dryer. Common make-up air openings are acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to the dryers. The dryer must be installed with provisions for adequate combustion and make-up air supply.

EXAMPLE: For a bank of eight (8) dryers, two (2) unrestricted openings measuring 3 feet by 2 feet (0.914 meters by 0.61 meters) (6 square feet [0.557 square meters]) are acceptable.

IMPORTANT: Make-up air openings should not be located in an area directly near where exhaust vents exit the building.

Allowances must be made for remote or constricting passageways or where dryers are located at excessive altitudes or predominantly low-pressure areas.

IMPORTANT: Make-up air must be provided from a source free of contaminating fumes such as dry cleaning solvent fumes. Make-up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components.

NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.

11

Image 15
Contents MDG50V Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Receiving and Handling Important InformationExplosion could Result Safety PrecautionsPage Specifications SpecificationsSpecifications UNPACKING/SETTING UP Installation ProceduresLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Vertical Venting Multiple Dryer Common Venting Illus. C Important Venting Reminders Electrical Requirements Electrical InformationMust be Provided Single-Phase 1ø Wiring Connections/HookupGround SINGLE-PHASE 1Ø Electrical Connection LeadsImportant a Circuit Servicing Each Dryer Must be Provided Service Wire Approx Circuit Phase AMP Draw GAS Information Natural Liquid Propane Page Page Preparation for OPERATION/START-UP GAS Models only Preoperational TestsCoin Models Preoperational InstructionsPage OPL Models Shutdown Instructions SERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsWarranty Routine Maintenance CleaningSuggested Cleaning Schedule Lubrication AdjustmentsLint Drawer Removal Standards TroubleshootingBlower motor is not operating does not start Microprocessor controller computer display reads dSFL GAS Models only Dryer operates but is taking too long to dry Dryer is making scraping noise at basket tumbler area Data Label Data Label InformationSerial Number Procedure for Functional Check Replacement Components

MDG50V specifications

The American Dryer Corp MDG50V is a powerful and efficient tumble dryer that has been expertly designed to meet the demands of commercial laundry facilities. This model is particularly favored for its robust features and innovative technologies that enhance productivity and minimize operational costs.

One of the standout features of the MDG50V is its impressive capacity. With a 50-pound drying capacity, this dryer can handle large loads, making it ideal for laundromats, hotels, and other commercial applications. Its high-performance design ensures that garments are dried thoroughly and efficiently, reducing turnaround time and boosting overall productivity.

The MDG50V incorporates advanced technology to optimize drying performance. Its state-of-the-art control system allows for precise temperature and time settings, enabling users to customize the drying cycle according to the specific needs of various fabrics. This flexibility not only preserves the quality of garments but also contributes to energy savings, as the dryer can be operated at optimal conditions tailored to each load.

Energy efficiency is a key characteristic of the MDG50V. The dryer features a high-efficiency heat exchanger that maximizes heat retention while minimizing energy consumption. This technology not only reduces operational costs but also aligns with environmentally-friendly practices by lowering the carbon footprint of your laundry operations.

The drum design of the MDG50V is another highlight, featuring a spacious and durable construction that facilitates better airflow. This ensures even drying and reduces the risk of overheating, all while allowing for gentler treatment of fabrics. The specially designed lifters within the drum improve the tumbling action, enhancing the drying efficiency and quality of the results.

Maintenance is also made easy with the MDG50V. The unit is designed with accessible components, allowing for simple cleaning and servicing, which further minimizes downtime. Additionally, its rugged construction and high-quality materials ensure a long lifespan, making this dryer a reliable investment for any commercial laundry business.

In conclusion, the American Dryer Corp MDG50V is a top-tier commercial tumble dryer, delivering a powerful combination of capacity, efficiency, and cutting-edge technology. Its user-friendly features, energy-saving capabilities, and exceptional performance make it a valuable asset for any laundry operation seeking to optimize its processes and enhance service quality.