MULTIPLE DRYER (COMMON) VENTING

If it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper. The individual ducts should enter the bottom or side of the main duct at an angle not more than 45° in the direction of the airflow.

The main common duct may be any shape so long as the minimum cross-sectional area is provided. The main duct should be tapered with the diameter increasing before each individual 8-inch (20.32 cm) duct is added (refer to Illus. C for horizontal venting and Illus. D for vertical venting).

IMPORTANT: No more than four (4) dryers maximum should be connected to one (1) main common duct with a vertical run.

NOTE: Distance between dryer single ducts being connected to the main common duct must be a minimum of 34-1/4” (87 cm) dryer width.

Ductwork should be laid out in such a manner where allowances are made at rear area of the dryer for removal of rear service panels or guards.

The illustrations on page 16 show the minimum cross section area for multiple dryer venting. These figures must be increased in proportion if the main duct run from the last dryer to where it exhausts has numerous elbows or is unusually long.

IMPORTANT: For extended ductwork runs, the cross section area of the duct can only be increased to an extent. For extended ductwork runs, a professional heating, venting, and air conditioning (HVAC) firm should be consulted for proper venting information.

Refer to page 16 for Multiple Dryer Horizontal Venting and Vertical Venting examples/illustrations.

IMPORTANT: Exhaust back pressure measured by a manometer at the dryer exhaust duct area must be no less than 0 and must not exceed 0.3 inches (0.74 mb) of water column (W.C.).

15

Image 19
Contents MDG50V Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Receiving and Handling Important InformationExplosion could Result Safety PrecautionsPage Specifications SpecificationsSpecifications UNPACKING/SETTING UP Installation ProceduresLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Vertical Venting Multiple Dryer Common Venting Illus. C Important Venting Reminders Electrical Requirements Electrical InformationMust be Provided Single-Phase 1ø Wiring Connections/HookupGround SINGLE-PHASE 1Ø Electrical Connection LeadsImportant a Circuit Servicing Each Dryer Must be Provided Service Wire Approx Circuit Phase AMP Draw GAS Information Natural Liquid Propane Page Page Preparation for OPERATION/START-UP GAS Models only Preoperational TestsCoin Models Preoperational InstructionsPage OPL Models Shutdown Instructions Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Cleaning Routine MaintenanceSuggested Cleaning Schedule Lubrication AdjustmentsLint Drawer Removal Standards TroubleshootingBlower motor is not operating does not start Microprocessor controller computer display reads dSFL GAS Models only Dryer operates but is taking too long to dry Dryer is making scraping noise at basket tumbler area Data Label Data Label InformationSerial Number Procedure for Functional Check Replacement Components

MDG50V specifications

The American Dryer Corp MDG50V is a powerful and efficient tumble dryer that has been expertly designed to meet the demands of commercial laundry facilities. This model is particularly favored for its robust features and innovative technologies that enhance productivity and minimize operational costs.

One of the standout features of the MDG50V is its impressive capacity. With a 50-pound drying capacity, this dryer can handle large loads, making it ideal for laundromats, hotels, and other commercial applications. Its high-performance design ensures that garments are dried thoroughly and efficiently, reducing turnaround time and boosting overall productivity.

The MDG50V incorporates advanced technology to optimize drying performance. Its state-of-the-art control system allows for precise temperature and time settings, enabling users to customize the drying cycle according to the specific needs of various fabrics. This flexibility not only preserves the quality of garments but also contributes to energy savings, as the dryer can be operated at optimal conditions tailored to each load.

Energy efficiency is a key characteristic of the MDG50V. The dryer features a high-efficiency heat exchanger that maximizes heat retention while minimizing energy consumption. This technology not only reduces operational costs but also aligns with environmentally-friendly practices by lowering the carbon footprint of your laundry operations.

The drum design of the MDG50V is another highlight, featuring a spacious and durable construction that facilitates better airflow. This ensures even drying and reduces the risk of overheating, all while allowing for gentler treatment of fabrics. The specially designed lifters within the drum improve the tumbling action, enhancing the drying efficiency and quality of the results.

Maintenance is also made easy with the MDG50V. The unit is designed with accessible components, allowing for simple cleaning and servicing, which further minimizes downtime. Additionally, its rugged construction and high-quality materials ensure a long lifespan, making this dryer a reliable investment for any commercial laundry business.

In conclusion, the American Dryer Corp MDG50V is a top-tier commercial tumble dryer, delivering a powerful combination of capacity, efficiency, and cutting-edge technology. Its user-friendly features, energy-saving capabilities, and exceptional performance make it a valuable asset for any laundry operation seeking to optimize its processes and enhance service quality.