American Dryer Corp MDG50MNV, MDG50PNH installation manual F.E. System In Action

Page 41

SECTION X

SENSORACTIVATED

FIRE EXTINGUISHING (S.A.F.E.) SYSTEM

S.A.F.E. System In Action

The exclusive SensorActivated Fire Extinguishing (S.A.F.E.) System will extinguish fires that may start in the drying basket (tumbler). A series of sensors positioned throughout the basket (tumbler) and interfaced with the microprocessor will trigger the S.A.F.E. system water jet(s) to quickly extinguish the flames. The water jet(s) remain on for 2 minutes and will automatically activate again if a fire condition remains or reignites. While the water jet(s) are activated, the basket (tumbler) will jog to move the water throughout the load. The microprocessor will display that the system was activated and will continue to display until the dryer is attended to.

We have tried to make this manual as complete as possible and hope you will find it useful. The manufacturer reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models.

37

Image 41
Contents MDG50PNH / MDG50MNV Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Safety PrecautionsPage Cu m SpecificationsSpecifications UNPACKING/SETTING UP Installation ProceduresLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Vertical Venting Multiple Dryer Common Venting Illus. C Electrical Requirements Electrical InformationGAS Single-Phase Electrical Lead Connections GAS Information Type of GAS Page Page Preparation for OPERATION/START-UP GAS Models only Preoperational TestsBasket Tumbler Coating Preoperational Instructions NON-COIN ModelsShutdown Instructions Dual Timer DryersReversing Timer SPIN/DWELL Adjustments Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Suggested Cleaning Schedule Routine MaintenanceCleaning Lubrication AdjustmentsLint Drawer Removal Data Label Information SectionviiSectionviii Procedure for Functional Check Replacement ComponentsPage Page Dual Timer Manual Reset Burner HI-LIMIT InstructionsPhase Sensoractivated Fire Extinguishing S.A.F.E. System F.E. System In ActionBefore YOU Start Check Local Codes and Permits InstallationTypical water supply Optional Manual Bypass F.E. System Theory of Operation F.E. System Diagnostics Page 09/16/08