a)Connect the water column test gauge (manometer) to the gas valve pressure tap (1/8" N.P.T.). Refer to the illustration on previous page (page 22).

b)Start the dryer ... with the burner on, the correct water column pressure (W.C.) reading in inches should be:

Natural Gas ..................................... 3.5 - 4 inches W.C. L.P. (liquid propane) Gas ................ 10.5 - 11 inches W.C.

When a gas dryer in first started (during initial time of installation and start-up), it has a tendency not to ignite on the first ignition attempt. This is due to the fact that the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the supply lines. During this purge period there may be insufficient gas pressure for ignition, which might cause the DSI module to go into the "LOCK-OUT" mode (the L.E.D. [light emitting diode] will LIGHT "RED" CONTINUOUSLY).

NOTE: During the purge period, check to be sure that ALL shut-off valves are open.

NOTE: To reset the DSI module if it is in the "LOCK-OUT" mode, open and close the main door, then restart the dryer.

c)If gas pressure is low, unscrew slotted regulator cover on top of the gas valve and turn regulator (pressure) adjustment screw (located underneath the cover) clockwise (CW) to increase the pressure.

2)Ignitor and Flame-Probe Assembly

The ignitor and flame-probe assembly consists of a ceramic insulated ignitor electrode, a ground rod, and a ceramic insulated flame-probe electrode. The GAP between the ignitor electrode and the ground rod is set, and must be maintained at 1/8" +/- 1/32" (.1250 +/- .03121).When the DSI module provides the high synchronous spark (14,000 volts) through the high voltage (HV) lead, a spark is produced over the GAP. When this spark is produced, the gas valve is opened. Upon ignition, the flame probe electrode (of the ignitor/flame-probe assembly) has high voltage provided to it that supplies a small current to ground through the flame. Once the current is sensed, it initializes the DSI module to sustain the gas flow (from the gas valve).

IMPORTANT: THE GAP SETTING ON THE IGNITOR/

FLAME-PROBE ASSEMBLY IS CRITICAL.

a) DSI Ignitor and Flame-Probe Assembly Adjustments

(1)The GAP on the ignitor and flame-probe

assembly must be set, and held at 1/8" +/- 1/32" (.1250 +/- .03121). If this GAP is not maintained (if the GAP is either to large or to small), the DSI module will indicate a system malfunction and go into the "LOCK-OUT" mode (the L.E.D. will

LIGHT "RED" CONTINUOUSLY).

23

Image 27
Contents Thru Retain This Manual In a Safe Place For Future Reference Page For Your Safety Table of Contents Section Cause Improper and Dangerous Operation Routine Maintenance Monthly Lubrication Adjustments Gas Enclosure, Air Supply and Exhaust Requirements Installation RequirementsElectrical and Gas Requirements Operational Service Check ProcedureHeat Section Component Description24 VAC Direct Spark Ignition DSI Module Repairable ODPH/RVW Troubleshooting The Direct Spark Ignition DSI System Direct Spark Ignition DSI Troubleshooting Terms definitions Page Three Visual Checks +9LUH Troubleshooting Flow Chart Quick ReferencePdqg Uhqwruli Retries Troubleshooting/System Detailed DiagnosisDSI Ignitor and Flame-Probe Assembly Adjustments Ignitor and Flame-Probe AssemblyPage Air Turbulence Serial numbers for the dryers Are Made of Brass and can be Easily Damaged Discontinue electrical power to the dryerPage General Overview Steam Coil System OperationPage Page Page Page Sprinkler Solenoid Valve Sprinkler System DescriptionSprinkler System Operation Require any adjustmentPage Page Supplies Before Servicing the Dryer HP Control Relay ReplacementMAN3169 Air Jet Assembly Page Leave enough movement for V-belt adjustment Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page Adjustment knob simply acts upon a spring rest located Filter/Regulator AssemblyOperation Door SystemsDiscontinue electric service to the dryer Pneumatic Automatic Door Replacement or Removal Cable Cylinder Replacement or Removal Right Load Door Glass Window Replacement Proximity Switch ReplacementPage Control Electrical System Page Page Emergency Stop button pushed SectionDrive motor is not operating does not start Blown drive motor and blower fan and impellor motor fuses Failed motors both blower fan/impellor motor and drive motor Failed microprocessor controller computer Dryer operates but is taking too long to dry Excessive noise and vibration Electrical Troubleshooting Path of the Door Circuit Door Circuit Theory of the Door CircuitJ3 but now pin #8 on both Drive Motor CircuitTheory of the Drive Circuit Path of Voltage for the Drive CircuitTheory of the Drive Circuit Blower Motor Circiut Theory of the Blower Motor CircuitPath of Voltage for the Blower/Fan Motor Circuit Theory of the Blower Motor Circuit Heat Circuit Gas Models Theory of the Heat Circuit GasPath of Voltage for the Heat Circuit Heat Circuit Steam Models Theory of the Heat Circuit SteamPath of Voltage for the Heat Circuit Steam Path of Voltage for the Cycle Done Circuit Cycle Done Circuit Theory of the Cycle Done CircuitDoor indicates door switch circuit is open Phase 5 OPL System DiagnosticsHeat Output LED Indicator LED Display IndicatorsPage Door LED Indicator ADC450310 1- 07/28/99-25
Related manuals
Manual 76 pages 49.12 Kb

AD-200 specifications

The American Dryer Corp AD-200 is a renowned commercial dryer that stands out in the market for its efficiency, performance, and durability. Designed for high-demand environments such as laundromats, hotels, and gym facilities, the AD-200 delivers robust performance while maintaining user-friendly operation.

One of the standout features of the AD-200 is its capacity. With a generous drum size, this dryer can handle large loads, making it ideal for businesses with heavy laundry demands. This not only maximizes productivity but also allows users to process more laundry in less time, which is crucial in high-turnover environments.

The AD-200 employs advanced drying technologies that promote faster drying times while minimizing energy consumption. Its innovative airflow design ensures even heat distribution throughout the drum, allowing laundry to dry uniformly without hot or cold spots. This feature enhances drying efficiency and helps in preserving the quality of fabrics, reducing wear and tear over time.

Energy efficiency is a key characteristic of the AD-200. It is equipped with an EcoDry system that optimizes the drying process, significantly reducing operating costs. This technology monitors moisture levels in the drum and adjusts drying times accordingly. By preventing excess energy use, the EcoDry system not only helps in saving on utility bills but also aligns with environmentally responsible practices.

The AD-200 is built for reliability and longevity. Constructed with high-quality materials, it features a heavy-duty stainless steel drum that resists scratches, dents, and corrosion. Additionally, the unit’s design incorporates easy access for maintenance and service, which can drastically reduce downtime and operational disruptions.

In terms of user-friendliness, the AD-200 comes with a simple control interface that allows operators to select drying cycles with minimal effort. The intuitive controls and clear display make it accessible for all staff members. The dryer also includes adjustable drying times and temperatures, giving users flexibility to cater to different fabric care requirements.

Overall, the American Dryer Corp AD-200 is a steadfast solution for commercial laundry applications. Its combination of capacity, efficiency, and durability makes it a preferred choice among business owners looking to enhance their laundry operations while keeping costs manageable. With cutting-edge technology and user-centric design, the AD-200 stands as a reliable asset in the realm of commercial drying solutions.