Graco Inc 308639L Technical Data, Seat Parts List Matrix Column, Ball Parts List Matrix Column

Page 24

Parts Lists

Seat Parts List (Matrix Column 4)

Digit

Ref.

Part No.

Description

Qty.

No.

 

 

 

 

 

3

101*

190840

SEAT; 316 SST

4

 

102*

113449

O-RING; PTFE

4

 

 

 

 

 

5

101*

190837

SEAT; TPE

4

 

102*

113449

O-RING; PTFE

4

 

 

 

 

 

6

101*

190836

SEAT; SantopreneR

4

 

102*

113449

O-RING; PTFE

4

 

 

 

 

 

G

101*

194217

SEAT; GeolastR

4

 

102*

113449

O-RING; PTFE

4

 

 

 

 

 

Ball Parts List (Matrix Column 5)

 

Ref.

 

 

 

Digit

No.

Part No.

Description

Qty.

 

 

 

 

 

1

201*

113253

BALL; PTFE

4

 

 

 

 

 

2

201*

113266

BALL; acetal

4

 

 

 

 

 

6

201*

113254

BALL; SantopreneR

4

 

 

 

 

 

G

201*

114754

BALL; GeolastR

4

 

 

 

 

 

Diaphragm Parts List (Matrix Column 6)

Digit

Ref.

Part No.

Description

Qty.

No.

 

 

 

 

 

5

301*

190839

DIAPHRAGM; TPE

2

 

15*

113265

SEAL, u-cup; nitroxile

2

 

 

 

nitrile

 

 

 

 

 

 

6

301*

190838

DIAPHRAGM;

2

 

 

 

SantopreneR

 

 

15*

113265

SEAL, u-cup; nitroxile

2

 

 

 

nitrile

 

 

 

 

 

 

G

301*

194218

DIAPHRAGM; GeolastR

2

 

15*

113265

SEAL, u-cup; nitroxile

2

 

 

 

nitrile

 

 

 

 

 

 

P

301*

15M510

BOLT–THROUGH

2

 

 

 

DIAPHRAGM; PTFE

 

 

302*

193414

SHIM

2

 

303*

190838

DIAPHRAGM, back-up;

2

 

 

 

SantopreneR

 

 

15*

113265

SEAL, u-cup; nitroxile

2

 

 

 

nitrile

 

 

 

 

 

 

*Included in Fluid Section Service Kit. See the Repair Kit Matrix on page 21 to find the correct kit for your pump.

Technical Data

Maximum fluid working pressure . . . . . . . . . . . . 120 psi (0.8 MPa, 8 bar)

Air operating range . . . . . . . . . . . . . . . . . . 20 to 120 psi (0.14 to 0.8 MPa, 1.4 to 8 bar)

Maximum air consumption . . . . . . . . . . . . . . . 325 scfm Air consumption at 70 psi and100 gpm

(480 kPa, 4.8 bar and 379 lpm) . . . . . . . . . . . . 120 scfm (1.26 m3/min)

Maximum free-flow delivery . . . . . 275 gpm (1,041 lpm) Maximum pump speed . . . . . . . . . . . . . . . . . . . 135 cpm Gallons (liters) per cycle . . . . . . . . . . . . . . . . . . 2.0 (7.6) Maximum suction lift (water)

Dry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 ft (2.5 m) Wet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 ft (8.5 m)

Maximum size pumpable solids . . . . . 3/8 in. (9.4 mm)

* Sound power level at 120 psi (0.8 MPa, 8 bar)

and 105 cpm . . . . . . . . . . . . . . . . . . . . . . . . . 101 dBa * Sound pressure level at 120 psi (0.8 MPa, 8 bar)

and 105 cpm . . . . . . . . . . . . . . . . . . . . . . . . . . 86 dBa * Sound pressure level at 50 psi (0.3 MPa, 3 bar)

and 50 cpm . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 dBa Air inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 npt(f) Maximum operating temperature . . . . . 150_ F (65_ C) Fluid inlet . . . . . . . . 3-in. ANSI 4-bolt / DIN 8-bolt flange Fluid outlet . . . . . . 3-in. ANSI 4-bolt / DIN 8-bolt flange Wetted parts . . . . . . . . . . . aluminum, PTFE, GeolastR

SantopreneR, TPE, plated steel, acetal, SST Weight . . . . . . . . . . . . . . . . approximately 150 lb (68 kg)

*Sound power level measured per ISO Standard 9614–2. Sound pressure measured 1 meter from pump. Geolastr and Santoprener are registered trademarks of the Monsanto Company.

TorxR is a registered trademark of Camcar, Division of Textron, Inc.

24 308639

Image 24
Contents Instructions Parts List ContentsEquipment Misuse Hazard 308639Hazardous Fluids Installation General InformationTightening Screws Before First Use Grounding Hazardous FluidsFLOOR-MOUNT Typical Installation KEYMountings Air LineFluid Lines Fluid Outlet LineChanging Manifold Orientation Fluid Pressure Relief ValveAir Exhaust Ventilation Toxic Fluid HazardVenting Exhaust AIR Pressure Relief Procedure Starting and Adjusting the PumpOperation Flush the Pump Before First UseMaintenance Preventive Maintenance ScheduleLubrication Flushing and StorageTroubleshooting Problem Cause SolutionService Repairing the Air ValveDisassembly See Fig Relieve the pressure Tools RequiredReassembly Ball Check Valve Repair Diaphragm Repair Disassembly Relieve the pressure Removing and Replacing Bearings and Air Gasket on302 301 Removing and Replacing Bearings and Air Gasket See Fig Detail of Bearings Through hole must be on bottomPump Matrix Husky 3275 Pumps, Series C232505, Aluminum 3275 Pump, Series C 24D619, Aluminum 3275 Pump, Series a Repair Kit Matrix For Husky 3275 Pumps, Series CParts Drawing 303 301 302 61 2 114 201 102 101 201* 102Parts Lists Air Motor Parts List Matrix ColumnFluid Section Parts List Matrix Column Digit Description QtyTechnical Data Seat Parts List Matrix ColumnBall Parts List Matrix Column Diaphragm Parts List Matrix ColumnTorque Sequence Dimensional Drawings Front ViewPump Mounting Hole Pattern Side ViewPerformance Charts Fluid Outlet PRESSURE--psi MPa, barFluid Pressure Curves AIR CONSUMPTION--scfm cubic meters/min Air Consumption Curves308639 Graco Warranties Graco InformationToll Free, 612-623-6921, 612-378-3505 Fax Graco Headquarters Minneapolis