Graco Inc 308639L Installation, General Information, Tightening Screws Before First Use Grounding

Page 4

Installation

General Information

DThe Typical Installation shown in Fig. 2 is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.

DAlways use genuine Graco parts and accessories.

DReference numbers and letters in parentheses refer to the callouts in the figures and in the Parts Drawing on page 22 and the Parts Lists on pages 23 and 24.

WARNING

HAZARDOUS FLUIDS

To reduce the risk of serious injury, splashing in the eyes or on the skin, and toxic fluid spills, never move or lift a

pump under pressure. If dropped, the fluid section could rupture. Always follow the Pressure Relief Procedure on page 9 before you move or lift the pump.

DThe pump is very heavy. If it must be moved, have two people lift the pump by grasping the outlet manifold (50). See the Parts Drawing on page 22.

Use a compatible thread sealant on all male threads. Tighten all connections firmly to avoid air or fluid leaks.

CAUTION

To avoid pump damage, do not overtighten the fittings to the pump.

Tightening Screws Before First Use

Grounding

WARNING

ELECTRIC SHOCK HAZARD

This pump must be grounded. The steps for grounding may differ from the way you ground other pumps. Read and

carefully follow the grounding instructions below before you operate the pump.

To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equipment.

Ground all of this equipment:

DPump: Connect a ground wire and clamp as shown in Fig. 1. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 12 ga (1.5 mm@) minimum ground wire (Y) into the slot in the lug (Z), and tighten the locknut securely. Connect the clamp end of the ground wire to a true earth ground. To order a ground wire and clamp, order Part No. 222011.

Y

X

W

Z

Before using the pump for the first time, check and retorque all external fasteners. See Torque Sequence, page 25. After the first day of operation, retorque the fasteners. Although pump use varies, a

Fig. 1

06318

general guideline is to retorque fasteners every two months.

4 308639

DAir compressor: Follow the manufacturer’s recommendations.

DAir and fluid hoses: Use only grounded hoses with a maximum of 500 ft (150 m) combined hose length to ensure grounding continuity.

DAll solvent pails used when flushing: Follow the local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts grounding continuity.

DFluid supply container: Follow the local code.

Image 4
Contents Instructions Parts List ContentsEquipment Misuse Hazard 308639Hazardous Fluids Installation General InformationTightening Screws Before First Use Grounding Hazardous FluidsFLOOR-MOUNT Typical Installation KEYMountings Air LineFluid Lines Fluid Outlet LineChanging Manifold Orientation Fluid Pressure Relief ValveAir Exhaust Ventilation Toxic Fluid HazardVenting Exhaust AIR Pressure Relief Procedure Starting and Adjusting the PumpOperation Flush the Pump Before First UseMaintenance Preventive Maintenance ScheduleLubrication Flushing and StorageTroubleshooting Problem Cause SolutionService Repairing the Air ValveDisassembly See Fig Relieve the pressure Tools RequiredReassembly Ball Check Valve Repair Diaphragm Repair Disassembly Relieve the pressure Removing and Replacing Bearings and Air Gasket on302 301 Removing and Replacing Bearings and Air Gasket See Fig Detail of Bearings Through hole must be on bottomPump Matrix Husky 3275 Pumps, Series C232505, Aluminum 3275 Pump, Series C 24D619, Aluminum 3275 Pump, Series aRepair Kit Matrix For Husky 3275 Pumps, Series CParts Drawing 303 301 302 61 2 114 201 102 101 201* 102Parts Lists Air Motor Parts List Matrix ColumnFluid Section Parts List Matrix Column Digit Description QtyTechnical Data Seat Parts List Matrix ColumnBall Parts List Matrix Column Diaphragm Parts List Matrix ColumnTorque Sequence Dimensional Drawings Front ViewPump Mounting Hole Pattern Side ViewFluid Outlet PRESSURE--psi MPa, bar Performance ChartsFluid Pressure Curves AIR CONSUMPTION--scfm cubic meters/min Air Consumption Curves308639 Graco Warranties Graco InformationToll Free, 612-623-6921, 612-378-3505 Fax Graco Headquarters Minneapolis