Performance Charts

Aluminum Husky 3275 Fluid Outlet Pressure

FLUID OUTLET PRESSURE––psi (MPa, bar)

Test Conditions: Pump tested in water with inlet submerged.

140 (0.98, 9.8)

120

 

 

 

 

 

 

 

 

 

Fluid Pressure Curves

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0.8, 8)

 

 

 

 

 

 

A at 120 psi (0.8 MPa, 8 bar) air pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

B at 100 psi (0.7 MPa, 7 bar) air pressure

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0.7, 7)

 

 

 

 

 

 

C at 70 psi (0.48 MPa, 4.8 bar) air pressure

 

 

 

 

 

 

B

 

 

D at 40 psi (0.28 MPa, 2.8 bar) air pressure

 

 

80

 

 

 

 

 

 

E at 20 psi (0.14 MPa, 1.4 bar) air pressure

 

 

 

 

 

 

 

 

 

(0.55, 5.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0.41, 4.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0.28, 2.8)

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0.14, 1.4)

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

30

60

90

120

150

180

210

240

270

 

 

 

(114)

(227)

(341)

(454)

(568)

(681)

(795)

(908)

(1022)

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (gpm/lpm) and operating air pressure (psi/MPa/bar):

1.Locate fluid flow rate along bottom of chart.

2.Follow vertical line up to intersection with selected fluid outlet pressure curve.

3.Follow left to scale to read fluid outlet pressure.

FLUID FLOW––gpm (lpm)

To calculate Pressure Head in feet at a specific fluid outlet pressure (psi):

pressure head, feet = (psi * 2.31) / specific gravity of fluid

To calculate Pressure Head in meters at a specific fluid outlet pressure (MPa):

pressure head, meters = (MPa * 102) / specific gravity of fluid

To calculate Pressure Head in meters at a specific fluid outlet pressure (bar):

pressure head, meters = (bar * 10.2) / specific gravity of fluid

308639 27

Image 27
Contents Contents Instructions Parts List308639 Equipment Misuse HazardHazardous Fluids Hazardous Fluids InstallationGeneral Information Tightening Screws Before First Use GroundingKEY FLOOR-MOUNT Typical InstallationFluid Outlet Line MountingsAir Line Fluid LinesToxic Fluid Hazard Changing Manifold OrientationFluid Pressure Relief Valve Air Exhaust VentilationVenting Exhaust AIR Flush the Pump Before First Use Pressure Relief ProcedureStarting and Adjusting the Pump OperationFlushing and Storage MaintenancePreventive Maintenance Schedule LubricationProblem Cause Solution TroubleshootingTools Required ServiceRepairing the Air Valve Disassembly See Fig Relieve the pressureReassembly Ball Check Valve Repair Diaphragm Repair Removing and Replacing Bearings and Air Gasket on Disassembly Relieve the pressure302 301 Removing and Replacing Bearings and Air Gasket See Fig Through hole must be on bottom Detail of Bearings24D619, Aluminum 3275 Pump, Series a Pump MatrixHusky 3275 Pumps, Series C 232505, Aluminum 3275 Pump, Series CFor Husky 3275 Pumps, Series C Repair Kit Matrix303 301 302 61 2 114 201 102 101 201* 102 Parts DrawingDigit Description Qty Parts ListsAir Motor Parts List Matrix Column Fluid Section Parts List Matrix ColumnDiaphragm Parts List Matrix Column Technical DataSeat Parts List Matrix Column Ball Parts List Matrix ColumnTorque Sequence Side View Dimensional DrawingsFront View Pump Mounting Hole PatternPerformance Charts Fluid Outlet PRESSURE--psi MPa, barFluid Pressure Curves Air Consumption Curves AIR CONSUMPTION--scfm cubic meters/min308639 Graco Headquarters Minneapolis Graco WarrantiesGraco Information Toll Free, 612-623-6921, 612-378-3505 Fax