| Controlling the Multiple Product | |
|
|
|
Transmission / Receiving Protocol
30.Elapsed time return(Command : d l) ► To read the elapsed time.
Transmission
[d][l][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[l][ ][Set ID][ ][OK/NG][Data][x]
*The data means used hours. (Hexadecimal code)
31.Temperature value (Command : d n) ► To read the inside temperature value.
Transmission
[d][n][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[n][ ][Set ID][ ][OK/NG][Data][x]
* The data is 1 byte long in Hexadecimal.
32.Lamp fault Check(Command : d p) ► To check lamp fault.
Transmission
[d][p][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[p][ ][Set ID][ ][OK/NG][Data][x]
Data 0 : Lamp Fault
1 : Lamp OK
2 : N/A(DPM/Power Off)
A19