service. In conjunction with the failed indication will be a code which indicates to the repair personnel where the problem is.

Press MENU to advance to the second Diagnostic screen.

The second Diagnostic screen evaluates external connections to the unit. The first category is Transducer input. If a transducer is detected, a message will indicate "connected".

This is an excellent way to confirm transducer connection. If a transducer is connected directly to the unit, the connection will be indicated here. If a switch is used, use Diagnostic to confirm the connections from each transducer. If a series of dashed lines is shown, then no transducer is connected or there is a problem with the transducer or cable.

The next categories indicate the connection of boat speed sensor and surface water temperature sensor. These accessory sensors can be purchased independently or together as a single sensor (see Available Accessories). If the sensors are connected and working properly, a "connected" message will appear.

Note: This feature only works when the boat is in motion as the paddle wheel on the speed sensor must rotate to be detected.

The voltage input category is especially helpful in diagnosing input voltage problems. The current input voltage will be displayed. If voltage fluctuations or power supply in excess of 16 VDC or less than 10 VDC is suspected, use the diagnostic screen to confirm input voltage. Often, small outboard motors do not effectively regulate voltage when operated at high engine speeds. Use Diagnostic while running the boat at high speeds to show the voltage gain. Also, if you are using the ProAngler in portable configuration or from the trolling motor battery, Diagnostic can be used to evaluate the health of the battery by showing the current voltage.

The total time category indicates the total time the unit has been in use since shipped from the factory.

Note: It is normal for some hours to be indicated in the total time when the unit is new due to factory testing.

While this is often of interest to the user, it is primarily a diagnostic tool for the repair technician should service be required. Press MENU again to exit Diagnostic.

Image 33
Contents Page Accessories Installation OverviewParts Supplied Determining How to Mount the Transducer Portable Mounting Alternate Transducers and Mounting MethodsTrolling Motor Mounting Thru-Hull MountingTransducer Exchange Beginning InstallationStep One Determine Where to Mount the Transducer Transom InstallationStep Three Assemble the Transducer Step Two Drill the Mounting HolesPage Step Five Adjust the Running Position of the Transducer Step Four Mount the Transducer to the TransomConfirm the pivot angle has not changed Page Step Six Route the Cable Inside the Hull Installation Step One Determine the Mounting LocationStep Two Test the Mounting Location Page Step Three Permanently Mount the Transducer Control Head Installation Step One Determine Where to MountStep Two Connect the Power Cable to the Boat Page Step Four Run the Cables Step Three Drill the Mounting HolesPage Your Humminbird is now ready for operation Step Five Assembling the Connector HolderTest the Installation Available Accessories Interpreting the ON-SCREEN Information Page Control Functions Page Page Page Page Page Page Page Using Diagnostic