Diagnostic Error Code

FRU/Action

 

 

 

001-027-XXX

1.

Run Setup

System Configuration/Setup error

2.

Flash the system. See “Flash update

 

 

 

procedures” on page 338

 

3.

System board

 

 

001-032-XXX

System board

System Device Controller failure

 

 

 

 

 

001-034-XXX

1.

Reboot the system

System Device Buffer Allocation failure

2.

Flash the system. See “Flash update

 

 

 

procedures” on page 338

 

3.

Run memory test

 

4.

System board

 

 

001-035-XXX

System board

System Device Reset condition detected

 

 

 

 

001-036-XXX

System board

System Register error

 

 

 

 

 

001-038-XXX

1.

Adapter card

System Extension failure

2.

System board

 

 

 

 

001-039-XXX

1.

Flash the system. See “Flash update

System DMI data structure error

 

procedures” on page 338

 

 

 

2.

System board

 

 

 

001-040-XXX

1.

Power-off/on system and re-test

System IRQ failure

2.

System board

 

 

 

 

001-041-XXX

1.

Power-off/on system and re-test

System DMA failure

2.

System board

 

 

 

001-195-XXX

Information only

System Test aborted by user

Re-start the test, if necessary

 

 

 

001-196-XXX

1.

Press F3 to review the log file

System test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 

001-197-XXX

1.

Make sure the component that is called

System test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

001-198-XXX

1.

If a component is called out, make sure

System test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Flash the system and retest. See “Flash

 

 

update procedures” on page 338

 

3.

Go to “Undetermined problems” on page

 

 

90

 

 

 

Chapter 7. Symptom-to-FRU Index 63

Page 69
Image 69
Lenovo 8098 manual Diagnostic Error Code FRU/Action 001-027-XXX Run Setup, XXX System board, XXX Reboot the system