Lenovo 8098 manual Diagnostic error codes

Models: 8098

1 352
Download 352 pages 24.24 Kb
Page 67
Image 67

Diagnostic error codes

Refer to the following diagnostic error codes when using the diagnostic tests. See “Running diagnostics tests” on page 50 for the specific type for information about the Diagnostic programs.

In the following index, X can represent any number.

Diagnostic Error Code

FRU/Action

 

 

000-000-XXX

No action

BIOS Test Passed

 

 

 

 

 

000-002-XXX

1.

Flash the system. See “Flash update

BIOS Timeout

 

procedures” on page 338

 

 

 

2.

System board

 

 

 

000-024-XXX

1.

Flash the system. See “Flash update

BIOS Addressing test failure

 

procedures” on page 338

 

 

 

2.

System board

 

 

 

000-025-XXX

1.

Flash the system. See “Flash update

BIOS Checksum Value error

 

procedures” on page 338

 

 

 

2.

Boot block

 

3.

System board

 

 

 

000-026-XXX

1.

Flash the system. See “Flash update

FLASH data error

 

procedures” on page 338

 

 

 

2.

Boot block

 

3.

System board

 

 

 

000-027-XXX

1.

Run Setup

BIOS Configuration/Setup error

2.

Flash the system. See “Flash update

 

 

 

procedures” on page 338

 

3.

Boot block

 

4.

System board

 

 

 

000-034-XXX

1.

Reboot the system

BIOS Buffer Allocation failure

2.

Flash the system. See “Flash update

 

 

 

procedures” on page 338

 

3.

Run memory test

 

4.

System board

 

 

 

000-035-XXX

1.

Flash the system. See “Flash update

BIOS Reset Condition detected

 

procedures” on page 338

 

 

 

2.

System board

 

 

 

000-036-XXX

1.

Flash the system. See “Flash update

BIOS Register error

 

procedures” on page 338

 

 

 

2.

Boot block

 

3.

System board

 

 

 

000-038-XXX

1.

Flash the system. See “Flash update

BIOS Extension failure

 

procedures” on page 338

 

 

 

2.

Adapter card

 

3.

System board

 

 

 

Chapter 7. Symptom-to-FRU Index 61

Page 67
Image 67
Lenovo 8098 manual Diagnostic error codes