Lenovo 8098 manual 030-199-XXX, XXX No action, 035-0XX-XXX RAID signal cable, XXX Information only

Models: 8098

1 352
Download 352 pages 24.24 Kb
Page 80
Image 80

Diagnostic Error Code

FRU/Action

 

 

 

030-198-XXX

1.

If a component is called out, make sure

SCSI interface test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 338

 

3.

Go to “Undetermined problems” on page

 

 

90

 

 

 

030-199-XXX

1.

Go to “Undetermined problems” on page

SCSI interface test failed, cause unknown

 

90

 

 

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 338

 

3.

Replace component under function test

 

 

035-000-XXX

No action

RAID interface Test Passed

 

 

 

 

 

035-0XX-XXX

1.

RAID signal cable

RAID interface Failure

2.

RAID device

 

 

3.

RAID adapter card, if installed

 

4.

System board

 

 

035-195-XXX

Information only

RAID interface Test aborted by user

Re-start the test, if necessary

 

 

 

035-196-XXX

1.

Press F3 to review the log file

RAID interface test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

035-197-XXX

1.

Make sure the component that is called

RAID interface test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

035-198-XXX

1.

If a component is called out, make sure

RAID interface test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 55

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 338

 

3.

Go to “Undetermined problems” on page

 

 

90

 

 

 

035-199-XXX

1.

See “Undetermined problems” on page

RAID interface test failed, cause unknown

 

90

 

 

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 338

 

3.

Replace component under function test

 

 

071-000-XXX

No action

Audio port Interface Test Passed

 

 

 

 

 

74Hardware Maintenance Manual

Page 80
Image 80
Lenovo 8098 manual 030-199-XXX, XXX No action, 035-0XX-XXX RAID signal cable, XXX Information only, 035-199-XXX