Humminbird ProAngler manual

Page 27

water, the 0-30' range would be selected). This provides the best display resolution and therefore the best target separation possible.

The Depth Range can be adjusted manually. Press MENU repeatedly until the Depth Range menu is visible. The two options available are "Auto" (Factory Setting) and "Manual". Pressing the DOWN ARROW enables "Manual" depth range control and an additional menu will appear which allows the user to adjust the current depth range setting. If no further button is pressed, the current depth range is selected as the desired range and the unit returns to normal operation.

Using "Manual" Depth Range control, the user can view sonar information from the area near the surface in great detail. If a depth range other than the current range is desired, pressing the DOWN ARROW to highlight "Adjust" will allow selection of one of the 9 available ranges. Simply press and hold the UP or DOWN ARROW button to scan through the available options. If a setting limit is reached, the audible "error" or multiple chirps will be heard and no further adjustment is allowed.

When "Manual" range is used, the unit no longer adjusts the Depth Range to the most appropriate range for bottom display. Often, the bottom may not be visible on-screen. The digital depth readout always determines the depth of the bottom, even if it is not visible on-screen.

When a Depth Range is selected manually and the Depth Range menu is still active (most recently used), further adjustment of the depth range can be achieved by simply pressing the appropriate

UP or DOWN ARROW button. The button press will bring the Depth Range menu on-screen and allows immediate adjustment of the range.

To return to "Automatic" Depth Range control, press the MENU button until the Depth Range menu appears on-screen and use the UP ARROW to select AUTO. The ProAngler returns to Automatic operation.

Zoom

Zoom is similar to Depth Range in that it controls the range of information displayed in the graphics area of the display. Zoom, however, allows selection of ranges beneath the surface so any area of water between the surface and the bottom can be enlarged to provide more detailed information. By using the full display to show a small area of coverage, the effective display resolution is increased, and the unit's ability to separate targets which are very close together is enhanced.

There are four different Zoom ranges available; 7 1/2', 15', 30', and 60'. These ranges are not directly user controlled but are instead dependent on the current depth range. In shallow water, when the 15' or 30' range is in use, the Zoom range is 7 1/2'. If the 60' or 120' range is in use, the Zoom range is 15', if a 180'-480' depth range is in use, the Zoom range is 30', and if the 600' range is in use, the Zoom range is 60'.

The ProAngler shows Zoom range in conjunction with the full depth

range. The Zoom range is shown on the left side of the screen and full range information is

Image 27
Contents Page Accessories Installation OverviewParts Supplied Determining How to Mount the Transducer Thru-Hull Mounting Alternate Transducers and Mounting MethodsPortable Mounting Trolling Motor MountingTransducer Exchange Beginning InstallationStep One Determine Where to Mount the Transducer Transom InstallationStep Three Assemble the Transducer Step Two Drill the Mounting HolesPage Step Five Adjust the Running Position of the Transducer Step Four Mount the Transducer to the TransomConfirm the pivot angle has not changed Page Step Six Route the Cable Inside the Hull Installation Step One Determine the Mounting LocationStep Two Test the Mounting Location Page Step Three Permanently Mount the Transducer Control Head Installation Step One Determine Where to MountStep Two Connect the Power Cable to the Boat Page Step Four Run the Cables Step Three Drill the Mounting HolesPage Your Humminbird is now ready for operation Step Five Assembling the Connector HolderTest the Installation Available Accessories Interpreting the ON-SCREEN Information Page Control Functions Page Page Page Page Page Page Page Using Diagnostic