Humminbird Legend 2000 manual Bottom Lock Zoom Mode / Manual Mode, Chart Speed

Page 10

USING THE LEGEND 2000 SERIES

BOTTOM LOCK ZOOM MODE / MANUAL MODE

To change the area of the bottom being zoomed, follow these steps:

1.Make sure the LEGEND 2000 SERIES is operating in BTM LOCK (Bottom Lock) mode.

2.Push the RANGE knob. An adjustment indicator appears by the lower zoom preview bar, indicating this is the selected depth limit for adjustment.

Note: Pushing the RANGE knob toggles between the upper and lower zoom preview bar adjustment. If the lower zoom preview bar is to be adjusted, push the RANGE knob until it is selected.

3.Rotate the RANGE knob to adjust the zoom preview bar. Moving the zoom preview bars closer together increases the display resolution in the zoomed window; moving them further apart decreases display resolution, but allows more area around the bottom to be viewed.

The indicators disappear after several seconds with no adjustment. The LEGEND 2000 SERIES continues to follow the bottom using the new range. Any change made to the zoom preview bars is remembered until the LEGEND 2000 SERIES is powered off, when the unit defaults to factory settings.

Manual Mode

MANUAL mode turns off automatic bottom tracking,

leaving control of the depth range to the user. Both the upper and lower depth ranges can be adjusted to show the bottom, or any other desired depth, in greater detail. When first switched to MANUAL mode, the LEGEND 2000 SERIES defaults to the current automatic depth range; however, after the manual depth ranges have been set, the LEGEND 2000 SERIES uses the new settings until it is powered off, when it defaults to factory settings.

MANUAL mode works best in areas of relatively flat bottom or if you are trolling slowly. It is also ideal for displaying a small area of the overall depth range in great detail if you are looking for fish at a specific depth.

To adjust the depth ranges manually, follow these steps:

1.Make sure the Legend 2000 Series is operating in Manual mode.

2.Push the Range knob. An adjustment indicator appears at the location of the Lower Depth Range, indicating that it is ready for adjustment.

Note: Pushing the Range knob toggles between the upper and lower depth range selection. If the Upper Depth Range is to be adjusted, push the Range knob until it is highlighted.

3.Rotate the RANGE knob to adjust the Depth Range. Clockwise rotation increases the depth; counterclockwise rotation decreases the depth. The display updates as the changes are made.

After several seconds without pressing or turning the knob, the DEPTH RANGE adjustment indicator will disappear from the screen automatically. The LEGEND 2000 SERIES does not make adjustments to keep the bottom information on- screen. If the depth is deeper or shallower than the ranges on the display, the bottom contour will not be visible.

The manual range settings made to the LEGEND 2000 SERIES default to factory settings after the unit is turned off.

Chart Speed

CHART SPEED selects the speed at which the bottom information moves across

the display. Options available range from 1 (very slow) to 8 (very fast). Selecting a faster rate shows more information in the CHART WINDOW, but it moves across the display very quickly. Selecting a slower rate keeps the information on the display longer, but the chart information becomes compressed and may be more difficult to interpret. Setting CHART SPEED in relation to boat speed is often preferred.

The CHART SPEED setting is retained in memory after the LEGEND 2000 SERIES is turned off. The factory setting is 6.

Manual Mode

Upper Depth Range Adjustment Indicator

8

Lower Depth Range Adjustment Indicator

Image 10
Contents Operations Manual Thank YOU All rights reservedTable of Contents Powering Up the Unit Using the Legend 2000 SeriesPerformance / Simulator / Powering UP the Unit Simulator and Feature MemoryUser Interface Chart Window Real Time Sonar / Chart WindowReal Time Sonar RTS Window Second Sonar Returns Chart Window / Bottoms / Fish AppearanceSloped Bottoms Structure ThermoclinesSonar Views / Control Panels Automatic ModeControl Panels Sonar Views Deep Models OnlyRange for viewing the second return, follow these steps Optimizing the Depth Range for Sonar Targets When the imageModes of Operation / Optimizing the Display At the lower right cornerManual Mode Bottom Lock Zoom Mode / Manual ModeChart Speed Light Sonar ViewRTS Window ContrastTemp Alarm Depth AlarmAlarm. The alarm will White LineFish ID Fish AlarmFish Sensitivity SimulatorMaintenance TroubleshootingUnit starts up in Simulator mode TroubleshootingTechsonic INDUSTRIES, INC ONE Year Limited Warranty Warranty / Service PolicyService Policy / Service Procedures For IN-WARRANTY service, complete the following stepsFor OUT-OF-WARRANTY service, complete the following steps 2000/2005 Specifications DEEP/2005 Deep Specifications