Humminbird Legend 2000 manual Optimizing the Depth Range for Sonar Targets When the image

Page 9
Adjustment Indicator

Optimizing the Depth Range for Sonar Targets When the image of the

bottom does not appear close to the bottom of the LCD display, the Legend 2000 Series is not fully optimizing the display to show sonar targets, such as fish, that are very close together. To enhance the ability of the unit to separate sonar

targets and to optimize the display for maximum resolution, follow these steps:

1.Make sure the Legend 2000 Series is operating in Automatic Mode.

2.Push the RANGE knob. An adjustment indicator appears at the lower right corner of the CHART WINDOW.

3.Turn the RANGE knob counterclockwise until the image of bottom is close to the bottom of the LCD display but still shows the area of interest.

USING THE LEGEND 2000 SERIES

MODES OF OPERATION / OPTIMIZING THE DISPLAY

Optimizing the Depth Range for Second Return To optimize the depth

range for viewing the second return, follow these steps.

1.Make sure the LEGEND 2000 SERIES is operating in Automatic.

2.Push the RANGE knob. An adjustment indicator appears

at the lower right corner of

the CHART WINDOW.

Optimized Display showing second return

3.Turn the RANGE knob clockwise until the second return is visible on the display.

4.To return the depth range to normal viewing, rotate the RANGE knob counterclockwise until the depth range stops updating.

Note: The second return does not appear at many of the deeper depth ranges. The appearance of the second return depends on depth of the water, water conditions, bottom hardness and the gain setting.

The LEGEND 2000 SERIES operates with this offset depth range until it is returned to the original settings, or the unit is turned off, after which the unit defaults to factory settings.

Optimized Display

Note: As the depth of the water increases, the LEGEND 2000 SERIES changes the depth range to keep the bottom on-screen. The LEGEND 2000 SERIES uses a depth range to keep the bottom contour close to the bottom of the display.

To return the depth range to normal viewing, turn the unit off and back on again using the GAIN knob. This is the only way to reset the depth range to normal viewing.

Bottom Lock Zoom Mode BTM LOCK (Bottom Lock) mode tracks the bottom similarly to Automatic mode; however, the display shows a full range view on right and a zoomed window on the left. The zoomed window provides added display resolution for separating sonar returns that are very close together, such as those caused by fish suspended close to the bottom.

Zoom Window

Zoom Preview

 

Bars

Bottom Lock Zoom Mode

As the depth changes, the LEGEND 2000 SERIES automatically keeps the bottom visible in the zoomed window and the full range view. In the full range view, horizontal zoom preview bars define the area of bottom being enlarged. The default setting varies based on the depth range; however, this setting can be changed to show more area around the bottom, or to show the bottom in greater detail.

7

Image 9
Contents Operations Manual All rights reserved Thank YOUTable of Contents Performance / Simulator / Powering UP the Unit Using the Legend 2000 SeriesPowering Up the Unit Simulator and Feature MemoryUser Interface Real Time Sonar / Chart Window Chart WindowReal Time Sonar RTS Window Sloped Bottoms Chart Window / Bottoms / Fish AppearanceSecond Sonar Returns Structure ThermoclinesControl Panels Automatic ModeSonar Views / Control Panels Sonar Views Deep Models OnlyModes of Operation / Optimizing the Display Optimizing the Depth Range for Sonar Targets When the imageRange for viewing the second return, follow these steps At the lower right cornerBottom Lock Zoom Mode / Manual Mode Manual ModeChart Speed RTS Window Sonar ViewLight ContrastAlarm. The alarm will Depth AlarmTemp Alarm White LineFish Sensitivity Fish AlarmFish ID SimulatorTroubleshooting MaintenanceTroubleshooting Unit starts up in Simulator modeWarranty / Service Policy Techsonic INDUSTRIES, INC ONE Year Limited WarrantyFor IN-WARRANTY service, complete the following steps Service Policy / Service ProceduresFor OUT-OF-WARRANTY service, complete the following steps DEEP/2005 Deep Specifications 2000/2005 Specifications