Host Interface
When the ODD receives this command, it responds to the command regardless of the DEV bit value; this means that the drive is unit 0 or 1.
When the ODD is device 0 (master), its response after the command is received depends on whether device 1 (slave) is connected.
When no device 1 is connected
The ODD sets 01h in the Error register and terminates the command.
When device 1 is connected
The ODD monitors the PDIAG- signal sent from device 1 for six seconds. If device 1 asserts the PDIAG- signal within this time, the ODD recognizes that the device 1
When the ODD is device 1
The ODD asserts the PDIAG- signal within five seconds. It sets 01h in the Error register and ends the command.
Table 4.22 Self-diagnosis detailed code
Detailed code | Meaning |
|
|
01h | Normally end |
|
|
Hardware error | |
| (For |
|
|
8xh | Device 1 ended abnormally. (For device 0 only) |
|
|