Omega DP18-RT1 specifications Specifications, Front View, Rear View, Range Selection, S1 Selector

Page 1

An OME GA Te c h n o l o g i e s Co m p a n y

DP18 Series

Model DP18-RT1

True RMS Ammeter

INSTRUCTION

SHEETM2107/1294

True RMS Ammeter for current transformer X/5

3 ½ DIGITS AC AMMETER, TRUE-RMS VALUES, WITH SELECTABLE RANGES ON THE SIGNAL CONDITIONER BY PLUG-IN JUMPERS. THE READING CAN NOT BE MODIFIED IN ENGINEERING UNITS, UNLESS THE AMPLIFIER IS MODIFIED. THEREFORE USING THE STANDARD AMPLIFIER THE DISPLAY WILL SHOW THE VALUES INDICATED ON THE TABLE. THE INPUT ALLOWS DIRECT CONNECTION TO A CURRENT TRANSFORMER (CT) WITH A 5 Aac. SECONDARY, WITHOUT NEED FOR AN INTERMEDIATE STEP DOWN.

SPECIFICATIONS

DISPLAYS

3 ½ digits, 7 segment, red LED

HEIGHT

0.56" (14.2 mm.)

SYMBOLS

1.8.8.8

DECIMALPOINTS

Selectable by jumpers

OVERRANGEINDICATION

Display flashes 1999

INPUTCONFIGURATION

Bipolar single

ZERO

Automatic

SPANADJUSTMENT

± 5 %

CONVERTER

Dual-slope, average value

SIGNALINTEGRATIONPERIOD

80 ms.

READ RATE

3.12 / sec.

RANGES

See table selection fig. 3

HOLD

Optional

NOISEREJECTIONNMR . . . . . . . . . . . 50 dB. 50/60 Hz. ACCURACY . . . . . . . . . . . . . . . . . . . . 0.2 % ± 1 count WARMUP TO RATED ACCURACY . . . 2 minutes SPANTEMPCO . . . . . . . . . . . . . . . . . . 150 ppm.

ZEROTEMPCO . . . . . . . . . . . . . . . . . . 2.5 µV/°C.

OPERATINGTEMPERATURE . . . . . . . 0 to 50 °C (32 to 122 °F) STORAGETEMPERATURE . . . . . . . . . -40 to 80 °C (-40 to 176 °F) WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . 310 gr. (0.68 lb)

CASE MATERIAL . . . . . . . . . . . . . . . . ABS, DIN 43700, black color STANDARDPOWER . . . . . . . . . . . . . . 115 Vac. ± 10 %, 50/60 Hz. POWERCONSUMPTION . . . . . . . . . . . 5.5 VA for AC. ELECTRICALCONNECTIONS . . . . . . . Push-in cable connectors BURN-IN . . . . . . . . . . . . . . . . . . . . . . . 24 h.

FIG. 1

 

 

 

FRONT VIEW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPAN OFFSET

SPAN : ADJUST THE MAXIMUM READING.

OFFSET : NOT IN SERVICE

SPAN ADJUSTMENT IS ACCESSIBLE BEHIND THE LOW DOOR.

REAR VIEW

FIG. 2

Setpoint R2

Setpoint R1

 

(option)

(option)

Isolated digital output

 

 

(option)

 

 

 

 

D

 

 

SIGNAL

C

 

1

B 10

INPUT

A

 

 

ANALOG

OUTPUT

+

 

-

 

(OPTION)

 

 

 

 

 

HOLD, latch the reading

 

 

display, while these pins

 

POWERSUPPLY

are linked

 

 

 

 

see instrument label

 

 

 

FIG. 3

SIGNALINPUT

5 Aac.

RANGE SELECTION

 

B

 

D

F

 

IC2

 

 

 

C

A

C

E

G

 

 

 

 

B

SIGNALCONDITIONER

 

 

 

 

 

 

 

A

COMPONENTSVIEW

 

 

 

S1 SELECTOR

PLACE THE PLUG-IN JUMPER ON THE SELECTOR S1, IN FUNCTION OF THE

NOMINALCURRENT TRANSFORMER, AND THE DECIMAL

POINT JUMPER ON THE CORRESPONDING POSITION (FIG. 5). TO OBTAIN THE INDICATED PERFOR-

MANCE, USE CURRENT TRANSFORMERS CLASS 0.5 OR BETTER

I NOMINAL

READING

CLOSE

RESOLUTION

Amp.AC

Amp.AC

JUMPER

Amp.AC

 

 

 

 

5

5.00

F

0.01

 

 

 

10

10.00

C

 

 

 

 

 

15

15.0

B

 

 

 

 

 

40

40.0

G

 

 

 

 

 

50

50.0

F

0.1

 

 

 

 

 

 

 

60

60.0

E

 

 

 

 

 

75

75.0

D

 

 

 

 

 

100

100.0

C

 

 

 

 

 

 

 

 

 

I NOMINAL

READING

CLOSE

RESOLUTION

Amp.AC

Amp.AC

JUMPER

Amp.AC

 

 

 

 

150

150.0

B

0.1

 

400

400

G

 

 

 

 

 

500

500

F

 

 

 

 

 

600

600

E

 

 

 

 

 

750

750

D

1

 

 

 

 

1000

1000

C

 

 

 

 

 

1500

1500

B

 

 

 

 

 

2000

1999

A

 

 

 

 

 

CCD1294APC2BA

Image 1
Contents Front View SpecificationsRear View Range SelectionSelection of Decimal Points and Special Options PowersupplyoptionsCONTROLOUTPUT/COMMUNICATIONSOPTIONS Decimalpointsselector