Omega Engineering CN1001-RTD manual Conditions Requiring Disassembly, RATING/PRODUCT Label

Page 16

SECTION 6. SETUP

6.1 CONDITIONS REQUIRING DISASSEMBLY

You may need to open up the meter for one of the following reasons:

To check or change the 115 or 230 Vac power jumpers.

To install or remove jumpers on the main board.

6.2CONDITIONS REQUIRING DISASSEMBLY

Disconnect the power supply before proceeding.

To remove and access the main board, follow these steps:

Disconnect the main power from the meter.

Remove the back case cover.

Lift the back of the main board upwards and let it slide out of the case.

Caution: The meter has no power-on switch, so it will be in operation as soon you apply power.

6.3 RATING/PRODUCT LABEL

This label is located on top of the meter housing (Refer to Figure 6-4).

6.4 MAIN BOARD POWER JUMPERS

Important: If you want to change the Factory preset jumpers, do the following steps; otherwise go to section 6.5.

Warning: Disconnect the power from the unit before proceeding. This device must only be reconfigured by a specially trained electrician with corresponding qualifications. Failure to follow all instructions and warnings may result in injury!

To check voltage jumpers, or to change from 115 V to 230 V ac:

1.Remove the main board from the case. Refer to Section 6.2.

2.Locate the solder jumpers W1, W2, and W3 (located near the edge of the main board alongside the transformer - refer to Figure 6-1).

3.If your power requirement is 115 V ac, solder jumpers W1 and W3 should be wired, but jumper W2 should not. If your power requirement is 230 V ac, solder jumper W2 should be wired, but jumpers W1 and W3 should not.

10

Image 16
Contents User’s Guide Servicing North America Table of Contents Output Configuration OT.CF List of Figures Page Standard Features DescriptionAvailable Accessories Unpacking Safety Considerations Safety ConsiderationsParts of the Meter Front PanelPart Description /DEV Button Connector Label ac power with dc detail Rear of the MeterRear of the Meter Rear Connector Description Main Board Power Jumpers Conditions Requiring DisassemblyRATING/PRODUCT Label Main Board Power Jumpers W1, W2, W3 Jumper Functions Panel Mounting Panel CUT-OUTSensor Input Main Power Connections Sensor Input Connections4-Wire RTD Input Connection Main Power ConnectionsMain Power Connection dc powered unit Analog and Relay Output Connections Analog Output ConnectionsTransistor Output Connections Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Side View Factory Preset Values Factory Preset ValuesCE Approvals Information Page Page Page WARRANTY/DISCLAIMER OMEGA…Of Course

CN1001-RTD specifications

The Omega Engineering CN1001-RTD is a highly regarded temperature sensing device renowned for its accuracy, durability, and versatility in industrial applications. RTD stands for Resistance Temperature Detector, which utilizes the principle that a material's electrical resistance changes with temperature. The CN1001-RTD exemplifies this technology, offering precise temperature measurement suited for various environments.

One of the standout features of the CN1001-RTD is its exceptional temperature range, capable of functioning effectively between -200°C and 850°C. This extensive range enables the CN1001-RTD to be employed in diverse industries, from food processing to pharmaceuticals, automotive, and HVAC applications. Furthermore, its robust construction allows for reliable performance in challenging conditions, where exposure to moisture, chemicals, and mechanical stress is common.

The CN1001-RTD employs a 100-ohm platinum resistor, known for its linear resistance-temperature characteristics and stability. Platinum provides a very predictable change in resistance, making it suitable for high-precision applications. The sensor incorporates advanced materials and construction techniques to ensure minimal drift and consistent readings over time, thereby reducing the need for frequent calibration and maintenance.

In addition to its high accuracy, the Omega CN1001-RTD features a fast response time, allowing for quick temperature readings that are essential in dynamic processes. This rapid response is particularly valuable in applications where temperature variations can occur rapidly, ensuring that systems are responsive and can be adjusted accordingly.

The CN1001-RTD also includes a variety of installation options, making it adaptable to various environments and configurations. Whether it's being used in a laboratory setting or in harsh industrial environments, its design accommodates different mounting styles, including threaded, flanged, and insertion types. This flexibility enhances usability and makes it easier to integrate into existing setups.

Moreover, Omega Engineering provides comprehensive support and documentation for the CN1001-RTD, ensuring that users can leverage its capabilities to their fullest. The company emphasizes quality control and precision engineering, resulting in a product that is trusted by professionals across many industries. Overall, the Omega Engineering CN1001-RTD stands as a top choice for those seeking a reliable, accurate, and versatile temperature sensing solution.