Omega Engineering CN1001-RTD manual Jumper Functions

Page 18

6.4 MAIN BOARD POWER JUMPERS (Continued)

Refer to Figure 6-2.

S2 jumpers are for sensor break indications:

*S2A jumper is not used

*S2B jumper is for positive sensor break (i.e. heating)

*S2C & S2D are not used

S3 jumpers are used for the following (refer to Table 6-1):

*To enable or disable the front panel push-buttons

*To allow for an extremely low resistance load for analog output

*To disable the MENU button

Test pins TP1 - TP11 are for testing purposes. Do not use as reading errors may result.

Table 6-1 Jumper Functions

 

 

Jumper

Description

S3-A

Install to enable front panel push-buttons.

 

Remove to disable all front panel push-buttons

 

 

S3-B

Removed. Install for factory calibration only.

 

 

S3-C

Normally removed. Install for analog voltage output

 

when load is less than 1 KW impedance. Care should be

 

taken when installing this jumper.

 

 

S3-D

Removed. Not used.

 

 

S3-E

If installed without S3-B, the MENU button locks out.

 

If you press the MENU button, the meter shows "LOCK".

12

Image 18
Contents User’s Guide Servicing North America Table of Contents Output Configuration OT.CF List of Figures Page Standard Features DescriptionAvailable Accessories Unpacking Safety Considerations Safety ConsiderationsParts of the Meter Front PanelPart Description /DEV Button Connector Label ac power with dc detail Rear of the MeterRear of the Meter Rear Connector Description Conditions Requiring Disassembly Main Board Power JumpersRATING/PRODUCT Label Main Board Power Jumpers W1, W2, W3 Jumper Functions Panel Mounting Panel CUT-OUTSensor Input Main Power Connections Sensor Input Connections4-Wire RTD Input Connection Main Power ConnectionsMain Power Connection dc powered unit Analog and Relay Output Connections Analog Output ConnectionsTransistor Output Connections Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Side View Factory Preset Values Factory Preset ValuesCE Approvals Information Page Page Page WARRANTY/DISCLAIMER OMEGA…Of Course

CN1001-RTD specifications

The Omega Engineering CN1001-RTD is a highly regarded temperature sensing device renowned for its accuracy, durability, and versatility in industrial applications. RTD stands for Resistance Temperature Detector, which utilizes the principle that a material's electrical resistance changes with temperature. The CN1001-RTD exemplifies this technology, offering precise temperature measurement suited for various environments.

One of the standout features of the CN1001-RTD is its exceptional temperature range, capable of functioning effectively between -200°C and 850°C. This extensive range enables the CN1001-RTD to be employed in diverse industries, from food processing to pharmaceuticals, automotive, and HVAC applications. Furthermore, its robust construction allows for reliable performance in challenging conditions, where exposure to moisture, chemicals, and mechanical stress is common.

The CN1001-RTD employs a 100-ohm platinum resistor, known for its linear resistance-temperature characteristics and stability. Platinum provides a very predictable change in resistance, making it suitable for high-precision applications. The sensor incorporates advanced materials and construction techniques to ensure minimal drift and consistent readings over time, thereby reducing the need for frequent calibration and maintenance.

In addition to its high accuracy, the Omega CN1001-RTD features a fast response time, allowing for quick temperature readings that are essential in dynamic processes. This rapid response is particularly valuable in applications where temperature variations can occur rapidly, ensuring that systems are responsive and can be adjusted accordingly.

The CN1001-RTD also includes a variety of installation options, making it adaptable to various environments and configurations. Whether it's being used in a laboratory setting or in harsh industrial environments, its design accommodates different mounting styles, including threaded, flanged, and insertion types. This flexibility enhances usability and makes it easier to integrate into existing setups.

Moreover, Omega Engineering provides comprehensive support and documentation for the CN1001-RTD, ensuring that users can leverage its capabilities to their fullest. The company emphasizes quality control and precision engineering, resulting in a product that is trusted by professionals across many industries. Overall, the Omega Engineering CN1001-RTD stands as a top choice for those seeking a reliable, accurate, and versatile temperature sensing solution.