This document describes how to configure the PowerLogic EM4000/EM4800 Series meters, using the PowerLogic configuration tool. It includes the following configuration tool information:

“System Set-up and Description” on page 1

“Configuration and Programming” on page 1

“Display Navigation” on page 3

“Communications Connections” on page 5

“Configuring the Meters” on page 7

“Login” on page 7

“Connecting to a Meter” on page 8

“Unit Field Configuration Tab” on page 10

“Manufacturing Tab” on page 19

“Meter Points (Circuits) Tab” on page 21

“Pulse Probes Tab” on page 24

“Completing the Meter Configuration” on page 26

This documentation is intended for those responsible for configuring the

PowerLogic meters.

System Set-up and Description

The configuration tool supports the following PowerLogic meters

PowerLogic EM4000 Series: PowerLogic EM4033 and EM4080 meters

PowerLogic EM4800 Series: PowerLogic EM4805, EM4833, and EM4880

meters

Depending on how the meters are installed and configured, they can meter 8, 12, or 24 individual meter points. The PowerLogic meters are designed for residential, commercial, and industrial use and display the power and consumption readings for each measurement point.

Configuration and Programming

The configuration tool is used to set any of the programmable parameters of the PowerLogic EM4000/EM4800 Series meter. The combination of the configuration tool and the state of the meter programming switches determine which parameters can be set or changed. As shown in Figure 1, the programming switches are two-position DIP switches labeled SW1, and are located inside the meter cover below the Display button. To enable meter configuration, both switches must be physically set to the ON (down) position (default).

©2013 Schneider Electric All Rights Reserved

1

Image 9
Contents PowerLogicTM Series EM4000/EM4800 Page Safety Information FCC Part 15 Notice Network Compatibility Notice for the Internal Modem Page Table of Contents Schneider Electric All Rights Reserved Configuration and Programming PowerLogic configuration toolProgramming access to meter parameters PowerLogicTM Series EM4000/EM4800 930-112-01-D.00 11/2013Parameter Read access Write access Activation time Display Navigation 11/2013 Parameter Read access Write access Activation timeNormal Mode Direct Connection Ethernet Requirements Communications ConnectionsNetwork Connection Ethernet Requirements Login Configuring the MetersConfiguration tool main window Connecting to a MeterDiscovered Units dialog box Main configuration window with configured parameters Unit Field Configuration TabField Parameter Description Unit Field Configuration tab parametersParameter Description Intervals tab configuration parameters11/2013 Parameter Description Types tab in the Report sectionTypes tab configuration parameters 930-112-01-D.00PowerLogicTM Series EM4000/EM4800 11/2013 Reporting Schedule tab configuration parametersIeee Calculations & Format tab configuration parametersBACnet tab in the Report section BACnet tab configuration parametersComms tab in the Report section Manufacturing Tab Comms tab configuration parametersEM4033xx EM4080xx EM4805xx EM4833xx EM4880xx List of supported PowerLogic metering configurationsMeter Points Circuits Tab Meter Point ConfigurationPowerLogicTM Series EM4000/EM4800 930-112-01-D.00 11/2013 Badge Numbering pane Reset Buttons Pulse Probes Tab Pulse Probes tab Saving the configuration settings Completing the Meter ConfigurationSending the configured settings to the meter PowerLogicTM Series EM4000/EM4800 930-112-01-D.00 11/2013 User notes PowerLogicTM Series EM4000/EM4800 930-112-01-D.00 11/2013 Page Schneider Electric PowerLogicTM Series EM4000/EM4800 Multi-Circuit Meters
Related manuals
Manual 32 pages 1.68 Kb

EM400, EM4800 specifications

Schneider Electric, a global leader in energy management and automation, offers advanced power monitoring solutions that enhance energy efficiency and operational effectiveness. The EM4800 and EM400 series are prominent products in Schneider Electric’s energy monitoring line, designed specifically for efficient energy consumption management in various industrial and commercial applications.

The EM4800 is a comprehensive energy meter that caters to larger facilities and energy-intensive operations. One of its main features is its ability to monitor multiple electrical parameters, including voltage, current, frequency, power factor, and total active/reactive energy. The device supports diverse communication protocols such as Modbus, Ethernet, and BACnet, allowing seamless integration into existing building management systems. This diversity in communication enhances visibility into energy usage and supports real-time monitoring, enabling facility managers to make informed decisions.

On the other hand, the EM400 series is designed for smaller applications while still delivering robust functionality. This series is tailored for monitoring power consumption in smaller commercial buildings or branch offices. EM400 meters focus on essential energy metrics but do so with a compact, easy-to-install design. With features like demand forecasting and peak load management, the EM400 provides valuable insights that help organizations optimize their energy usage.

Both models come equipped with advanced technologies such as harmonic analysis, which is crucial for understanding power quality and mitigating potential risks associated with harmonic distortion. The user-friendly interface of these devices facilitates quick access to energy data, making it simple for users to analyze consumption patterns and identify opportunities for energy savings.

In concurrence with Schneider Electric’s commitment to sustainability, both the EM4800 and EM400 series emphasize energy conservation by promoting efficient energy practices. Users can leverage the collected data to reduce energy costs, enhance equipment performance, and contribute to environmental sustainability efforts.

In summary, Schneider Electric’s EM4800 and EM400 energy meters combine innovative technology with practical features aimed at improving energy management. Their advanced monitoring capabilities, versatile communication options, and focus on power quality make them essential tools for organizations seeking to enhance operational efficiency while reducing their carbon footprint. By investing in these cutting-edge energy solutions, businesses can take significant strides towards sustainable energy management and operational excellence.