Raymarine ST40 manual Instrument

Page 23

14

ST40 Compass Instrument Owner’s Handbook

The Fluxgate Compass transducer must also be sited:

At least 0.8 m (2 ft 6 in) away from the vessel's steering compass to avoid deviation in both compasses.

On a bulkhead below deck.

Note: On steel vessels the Fluxgate Compass transducer can be mounted above deck. When mounted above deck, performance may be impaired due to increased motion.

To allow reasonable access for installation and servicing.

Away from any equipment or other installation which may shield the transducer or otherwise disturb the earth’s magnetic field, e.g. large ferrous or magnetic items, engines, communications equipment or cabling.

On a vertical mounting surface. Where necessary, make up a suitable nonferrous wedged packing piece to provide the necessary vertical surface.

Instrument

 

 

 

 

 

55 mm

70 mm

 

 

(2.2 in)

(2.8 in)

ST40

 

 

 

126 mm (5.0 in)

 

30 mm (1.2 in)

 

 

 

minimum cable clearance

 

21 mm

17 mm

 

Instrument dimensions

(0.8 in)

(0.67 in)

D4644-2

CAUTION:

The presence of moisture at the rear of the instrument could cause damage either by entering the instrument through the breathing hole or by coming into contact with the electrical connectors.

Each instrument must be positioned where:

It is easily read by the helmsman or navigator

It is protected against physical damage

It is at least 230 mm (9 in) from a compass

There is reasonable rear access for installation and servicing

The rear of the instrument is protected from water.

Image 23
Contents Distributed by ST40 Compass Instrument Copyright Raymarine Limited Handbook information Important informationEMC conformance ST40 Compass Instrument Owner’s Handbook Contents Installation Preface ST40 Compass Instrument Parts suppliedIntroduction Operating proceduresSilencing alarms OperationNormal Operation Adjust Backlighting Backlighting and contrast adjustmentLocked heading screen Screen descriptionsCompass heading screen Enabling/disabling alarm AlarmsOff course active alarm Man overboard alarm repeatedST40 Compass Instrument Owner’s Handbook Servicing and safety Maintenance and Fault FindingMaintenance Instrument Fault findingPreliminary procedures Fixing faultsLow battery Assistance EMC installation guidelines InstallationPlanning your installation Connections to Other Equipment Tools requiredSuppression Ferrites Fluxgate Compass transducer Site requirementsInstrument Introduction ProceduresInstallation Fitting Fluxgate Compass transducerRunning transducer cable Connections to the instrument Stand-alone connections SeaTalk connections Fitting the instrumentCut hole Screw stud into instrument Desktop Mounting BracketCalibration requirement EMC conformance CalibrationUser calibration User Calibration Dealer calibration Intermediate calibrationDealer Calibration Instrument Specification ST40 Compass Instrument Owner’s Handbook MOB GlossaryST40 Compass Instrument Owner’s Handbook EMC IndexLinearising transducer Transducer Locked heading Auto ST40 Instrument Template Page Warranty Limitations Limited Warranty CertificateUnited States of America UK, Europe, Middle East, Far East Factory Service Centers
Related manuals
Manual 43 pages 51.05 Kb