Chapter 4: Calibration

25

4.3 Intermediate calibration

Intermediate calibration enables you to:

Check the instrument software version.

Check the instrument status - either master (shown as RPTR NO) or repeater (shown as RPTR YES).

You cannot make any adjustments in Intermediate calibration.

Follow the procedure in the Intermediate calibration flow diagram.

INTERMEDIATE CALIBRATION

During normal operation

hold down

and

for approximately 4 seconds

Software

 

 

version

 

Note:

 

 

 

 

If there is no key activity when

 

 

the Software version screen

 

 

is displayed, calibration will

 

 

time out to normal operation

 

 

after 5 seconds,

ST40

 

COMPASS

Instrument status

CAL

ST40

COMPASS

To return to normal operation from either screen,

hold down and for approximately 2 seconds

4.4 Dealer calibration

Dealer calibration enables you to set:

User calibration on/off.

Boat show mode on/off.

D4781-2

Dealer calibration also gives access to the Factory defaults screen. This enables you to reapply the factory settings if you want to reset the instrument to a known operating condition.

Follow the procedure in the Dealer calibration flow diagram.

Image 34
Contents Distributed by ST40 Compass Instrument Copyright Raymarine Limited EMC conformance Important informationHandbook information ST40 Compass Instrument Owner’s Handbook Contents Installation Preface Parts supplied ST40 Compass InstrumentOperation Operating proceduresSilencing alarms IntroductionNormal Operation Backlighting and contrast adjustment Adjust BacklightingCompass heading screen Screen descriptionsLocked heading screen Man overboard alarm repeated AlarmsOff course active alarm Enabling/disabling alarmST40 Compass Instrument Owner’s Handbook Maintenance Maintenance and Fault FindingServicing and safety Fixing faults Fault findingPreliminary procedures InstrumentLow battery Assistance Planning your installation InstallationEMC installation guidelines Suppression Ferrites Tools requiredConnections to Other Equipment Site requirements Fluxgate Compass transducerInstrument Fitting Fluxgate Compass transducer ProceduresInstallation IntroductionRunning transducer cable Connections to the instrument Stand-alone connections Fitting the instrument SeaTalk connectionsCut hole Desktop Mounting Bracket Screw stud into instrumentCalibration requirement User calibration CalibrationEMC conformance User Calibration Intermediate calibration Dealer calibrationDealer Calibration Instrument Specification ST40 Compass Instrument Owner’s Handbook Glossary MOBST40 Compass Instrument Owner’s Handbook Index EMCLinearising transducer Transducer Locked heading Auto ST40 Instrument Template Page Limited Warranty Certificate Warranty LimitationsFactory Service Centers United States of America UK, Europe, Middle East, Far East