Raymarine ST40 manual User Calibration

Page 33

24

ST40 Compass Instrument Owner’s Handbook

USER CALIBRATION

During normal operation

hold down and for approximately 2 seconds

Entry screen

Note:

 

If there is no key

 

activity when the

 

Entry screen is

 

displayed, calibration

 

will time out to

ST40

COMPASS normal operation

 

after 5 seconds,

Set compass

15 (fast)

heading

 

response CAL

 

ST40

COMPASS

 

1 (slow)

Set heading

Increase

alignment

 

CAL

 

Flashing ST40

COMPASS

segment = North

Decrease

 

Deviation

CAL

ST40

COMPASS

When linearisation successful

(3 beeps)

Set variation

CAL

Increase value

2 turns

minimum

To bypass

ST40

COMPASS

Decrease value

HDGT

Set True/Magnetic

CAL

To linearise compass

Linearise transducer

CAL

ST40

COMPASS

linearisation

If vessel is turned too fast during linearisation, a SLO legend is displayed

ST40

COMPASS

RepeaterMaster

To save your settings and return to normal operation from any screen,

hold down and for approximately 2 seconds

D4780-2

Image 33
Contents Distributed by ST40 Compass Instrument Copyright Raymarine Limited Important information EMC conformanceHandbook information ST40 Compass Instrument Owner’s Handbook Contents Installation Preface ST40 Compass Instrument Parts suppliedSilencing alarms Operating proceduresOperation IntroductionNormal Operation Adjust Backlighting Backlighting and contrast adjustmentScreen descriptions Compass heading screenLocked heading screen Off course active alarm AlarmsMan overboard alarm repeated Enabling/disabling alarmST40 Compass Instrument Owner’s Handbook Maintenance and Fault Finding MaintenanceServicing and safety Preliminary procedures Fault findingFixing faults InstrumentLow battery Assistance Installation Planning your installationEMC installation guidelines Tools required Suppression FerritesConnections to Other Equipment Fluxgate Compass transducer Site requirementsInstrument Installation ProceduresFitting Fluxgate Compass transducer IntroductionRunning transducer cable Connections to the instrument Stand-alone connections SeaTalk connections Fitting the instrumentCut hole Screw stud into instrument Desktop Mounting BracketCalibration requirement Calibration User calibrationEMC conformance User Calibration Dealer calibration Intermediate calibrationDealer Calibration Instrument Specification ST40 Compass Instrument Owner’s Handbook MOB GlossaryST40 Compass Instrument Owner’s Handbook EMC IndexLinearising transducer Transducer Locked heading Auto ST40 Instrument Template Page Warranty Limitations Limited Warranty CertificateUnited States of America UK, Europe, Middle East, Far East Factory Service Centers