DESCRIPTION

The multi-function gas controls combine into a single package the functions of 3-position gas cock, main gas valve, pressure regulator and 100% shut-off automatic pilot. The pilot gas outlet accepts a 14” pilot line connec- tion.

This model features a slow opening main valve that provides a softer ignition and E.C.O. connections.

To permit replacement of a variety of valve sizes, some models are furnished with two reducer bushings (two 34” to 12”). Also included is an E.C.O. jumper wire that allows this valve to be used on an installation without electrical cut off device.

Electrical Rating:

Voltage: 24 Volts, (30 Volts Max.), 60 Hz.

Current Rating: 0.23 Amps

Type of Gas

 

Natural Gas

 

Pressure Rating: 12 lb. per sq. in. (14” W.C.)

 

Pressure Regulator Setting:

 

Adjustable from 2.5 to 5.0" W.C.

 

(Factory preset for 3.5" W.C.)

 

Ambient Temperature: -40°to 175°F

 

Thermocouple:

 

30 millivolt type

 

CONTENTS

 

Description

1

Specifications

1

Precautions

2

Installation

2

Main Piping Connection

 

Pilot Gas Connection

 

Energy Cut Off (E.C.O.) Connection

 

Thermocouple Connection

 

System Wiring

 

Adjustment

4

Pilot Gas Adjustment

 

Pressure Regulator Adjustment

 

Pilot Lighting Instructions and Precautions

5

ON

PILOT OFF

E.C.O

SPECIFICATIONS

PIPE SIZES/CAPACITIES

 

Capacity (BTU/hr) at

 

1” pressure drop across valve

 

 

 

Pipe Size

Nat. Gas

LP Gas

(1000 BTU/cu. ft.,

(2500 BTU/cu. ft.,

(inches)

64 Sp. Gr.)

1.53 Sp. Gr.)

12” x 38

100,000

162,000

12” x 12

230,000

372,600

12” x 34

230,000

372,600

34” x 34

280,000

453,600

Upright, 90°from upright or vertical

UPRIGHT

INLET BOSS

UP OR DOWN

 

LEFT OR RIGHT

ON

OFF

NOTE: Control shown may not be identical to replacement control.

Figure 1. Gas valve mounting positions

WHITE-RODGERS DIVISION

 

 

EMERSON ELECTRIC CO.

 

PART NO. 37-5825B

9797 REAVIS ROAD, ST. LOUIS, MO 63123-5398

 

(314) 577-1300, FAX (314) 577-1517

Printed in U.S.A.

Replaces 37-5825A

9999 HWY. 48, Markham, ONT, L3P 3J3

0024

 

(905) 475-4653, FAX (905) 475-4625

 

 

Image 1
Contents Description SpecificationsLeaks Immediately Installation Main Piping ConnectionsPilot GAS Connection System WiringEnergy CUT OFF E.C.O Connection Thermocouple ConnectionPressure Regulator Adjustment Pilot Flame AdjustmentFor Your Safety Read Before Lighting Pilot Lighting Instructions Precautions