Emerson SA-1 manual Installation Instructions, Installation for Contactor Controlled Load

Page 2

2 sa-1

Automatic Snow/Ice Melting Controller — Installation & Operation Instructions

INSTALLATION INSTRUCTIONS

1.Mount the SA-1 securely in upright position in an open space, in direct contact with snowfall pattern with a .5" (12.70mm) NPT mounting connector. The unit is water-resistant, but it is not designed to be submerged or immersed in water. Ensure that the mounting location is close, less than 2.5 ft (76.20cm) to the electrical junction box. See Fig. 4a &4b.

2.The SA-1 can be connected to the building power supply as per Fig. 2 or Fig. 3. Before connecting the controller to the electrical power supply, consult the local, state or provincial, and national electrical code. The electrical code may require a Ground Fault Protection device to be used.

3.Ensure that all pipe connections are sealed to prevent any penetration of water inside of conduit or electrical junction box.

SA - 1

OPTIONAL MANUAL SWITCH OR TIMER

AWG #12 RED/YELLOW

AWG #12 RED/YELLOW

SNOW MELTING

CABLE

AWG #18 BLACK

AWG #18 WHITE

OPTIONAL

ON/OFF

SWITCH

Figure 2 — Installation for Direct Control of Load

*Electrical code may require use of a ground fault protection device.

SA - 1

AWG #12 RED/YELLOW

AWG #12 RED/YELLOW

AWG #18 BLACK

AWG #18 WHITE

OPTIONAL MANUAL SWITCH OR TIMER

COIL

120

VAC

OPTIONAL

ON/OFF

SWITCH

SNOW MELTING CABLE

Figure 3 —

Installation for Contactor Controlled Load

*Electrical code may require use of a ground fault protection device.

US

T. (800) 537-4732 / F. (888) 324-2440

CAN

T. (800) 794-3766 / F. (800) 361-4574

www.easyheat.com

Image 2 Contents
SA-1 GeneralInstallation Instructions Installation for Contactor Controlled LoadElectrical Specifications Operation InstructionsLimited Warranty Disclaimer