A-2

A-2

INSTALLATION

TECHNICAL SPECIFICATIONS - Commander 300

 

 

INPUT - DIESEL ENGINE

 

 

Make/Model

Description

Speed (RPM)

Displacement

Starting

Capacities

 

 

 

 

System

 

Deutz

3 cylinder

1800 Full Load

125 cu. in.

Electric

Fuel: 25 gal.

F3L 1011F

Air/cooled

1900 High Idle

(2.05 liters)

12 VDC

(94.6 liters)

 

diesel

1400 Low Idle

 

 

 

 

31 HP

 

 

 

Oil: 6.3 qt.

 

@ 1800 RPM

 

 

 

(6.0 liters)

 

RATED OUTPUT - WELDER

 

Duty Cycle

Welding Output

Volts at Rated Amps

100%

300 amps (DC Multi-purpose)

32 volts

60%

375 amps (DC Multi-purpose)

34 volts

 

OUTPUT - WELDER AND GENERATOR

Welding Range

Max. Open Circuit Voltage

Auxiliary Power1

30 - 300 Amps DC

87 OCV

120/240 VAC

in 5 Ranges

@ 1900 RPM

10,000 Watts, 60 Hz.

 

 

100% Duty Cycle

 

PHYSICAL

DIMENSIONS

 

 

Height2

Width

Depth

Weight

 

42.0 in.

31.5 in.

63.1 in.

1325 lbs.

 

1066.8 mm

800.1 mm

1602.7 mm

1683 lbs.(601 kg)

 

 

 

 

 

 

1Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2Top of Enclosure. Add 8.9” (16mm) for exhaust.