POWER MODULE TEST (continued)

FIGURE F.26 – IGBT TEST

POWER MODULE (CHOPPER PC BOARD)

REMOVE LEADS

HEAT SINK

Return to Section TOC

Return to Master TOC

CHECK IGBT FOR “SHORTS”

5.Using the analog ohmmeter, connect the pos- itive meter probe to the heat sink and the neg- ative meter probe to the positive capacitor ter- minal on the chopper PC board. See Figure F.26. The resistance reading should be very high (over 20,000 ohms).

6.Reverse the meter probe leads. The resis- tance should be very high (over 20,000 ohms). It the resistance is low in either Step 5 or 6, the IGBT may be shorted or leaky.

7.Repeat Steps 4 and 5 for the other module.