FLASHING AND ROTOR VOLTAGE TEST (continued)

FIGURE F.12 – ROTOR BRUSH LEADS

#200A

#200B

#201

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Using the 3/8" wrench, remove the sheet metal screws from the left front case side.

2.Carefully remove the left case side.

3.Set the volt/ohmmeter to the DC volts posi- tion.

4.Connect the positive meter probe to the brush nearest the rotor lamination (leads #200A and #200B). See Figure F.12.for location.

5.Connect the negative meter probe to the other brush (lead #201).

6.Start the engine and run it at high idle speed (1900 RPM). Check the voltage reading on the meter. It should read approximately 160VDC.