F-12

TROUBLESHOOTING & REPAIR

 

 

 

 

F-12

 

 

 

 

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

 

 

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELDING PROBLEMS

 

 

 

 

 

 

 

The welding arc

is “cold.”

The

 

1. Check for loose or faulty connec-

1.

Check for the correct OCV at the

engine runs normally. The auxiliary

 

tions at the weld output terminals

 

welding output terminals.

If the

power is normal.

 

 

 

and welding cable connections.

 

correct voltage is present at the

 

 

 

 

2. Make sure the work clamp has a

 

output terminals, check for loose

 

 

 

 

 

connection on the heavy current

 

 

 

 

clean connection to the work

 

 

 

 

 

 

carrying

leads

inside

the

 

 

 

 

piece.

 

 

 

 

 

 

Commander

300.

 

See the

 

 

 

 

 

 

 

 

 

 

 

3. The welding cables may be too

 

Wiring Diagram.

 

 

 

 

 

 

 

long or coiled, causing an

2.

If the OCV is low at the welder

 

 

 

 

excessive voltage drop.

 

 

 

 

 

output terminals,

perform the

 

 

 

 

 

 

 

 

 

 

4. Make sure the electrode (wire,

 

Engine

Throttle

Adjustment

 

 

 

 

gas, voltage, current, etc.) is

 

Test.

 

 

 

 

 

 

 

 

 

correct for the process being

3.

Perform

the

Output

Rectifier

 

 

 

 

used.

 

 

 

 

 

Bridge Test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Make sure the machine settings

4.

Perform

the

Stator

Voltage

 

 

 

 

match the weld application.

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Perform

the

Power

Module

 

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

 

6.

Perform the Control Input Test.

 

 

 

 

 

7.

Perform

the

Feedback

Input

 

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

 

8.

Perform the PWM Output Test.

 

 

 

 

 

9.

If so equipped, perform the

 

 

 

 

 

 

Display

Board

Calibration

 

 

 

 

 

 

Test.

 

 

 

 

 

The welding arc

is “hot”.

The

 

1. Make sure the electrode (wire,

1.

Perform

the

Power

Module

engine runs normally. The auxiliary

 

gas, voltage, current, ect.) is

 

Test.

 

 

 

 

 

power is normal.

 

 

 

correct for the process being

2.

Perform the Control Input Test.

 

 

 

 

used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Make sure the machine settings

3.

Perform

the

Feedback

Input

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

match the weld application.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Perform the PWM Output Test.

 

 

 

 

 

5.

If so equipped, perform the

 

 

 

 

 

 

Display

Board

Calibration

 

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

COMMANDER 300

Page 68
Image 68
Lincoln Electric SVM145-B service manual Welding Problems