Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-95

F-95

TROUBLESHOOTING & REPAIR

STATOR/ROTOR REMOVAL AND REPLACEMENT

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).

TEST DESCRIPTION

The following procedure will aid the technician in removing and replacing the Commander 300 stator and rotor.

MATERIALS NEEDED

3/8" Wrench

Slot head screw driver

7/16" Wrench

Phillips head screw driver

1/2" Wrench

Gear puller (small)

3/4" Wrench

Hoist

1" Open end wrench

Feeler gauge (for air gap check)

1-1/8" Wrench

 

This procedure should take approximately 512 hours to perform.